Texas Instruments bq76PL536A Quick Start Manual Download Page 10

Evaluation Software Details

www.ti.com

LAST CRC

The last CRC received by the GUI was incorrect for the contents of the packet. This
usually indicates a communication error caused by improper connection, excessive
cabling, etc. The cause of the communication error should be corrected before continuing.

LOG

Green if a log file is being written to. Logging is useful to capture information about cell or
interface behavior over long periods of time

STACK

At least one device was found during auto-addressing or rebuild addresses. This indicates
that the bottom device in the stack was found, is powered, not in POR, and the ribbon
cable from the Aardvark to the EVM is connected correctly. This verifies the cabling and
connection all the way to the IC.

INTERFACE

The Aardvark USB-SPI interface adapter was successfully found and communicated with.
This verifies the cabling and driver to the adapter.

5.1.5

Global Registers

DEVICE

The Address of the device currently being communicated with. Change to access
different devices in the stack. “BROADCAST” mode also available to send a single
command to all devices in the stack. (In BROADCAST mode, no data are shown – the
interface can only display data from one device at a time.

STACK HT.

The number of devices found during the last AUTO-ADDRESS or REBUILD-
ADDRESS cycle.

POLL

Check or un-check this box to turn polling on or off. Note that many menu items are
unavailable during polling – turn polling off to access them.

RATE

This list box allows choosing a polling rate between 100ms and 60s. The LED
illuminates green each time the GUI polls the device stack. Useful as a heartbeat
indicator when polling or logging is active. A setting “Fast” is also available. In this
position, the WinGUI will poll as fast as possible, with only Windows operating system
slowing it down. On most systems, this results in a poll every 10-20ms, but your results
may vary depending on the speed of your CPU and other tasks that are running.

LOG STACK

Enables or disables data logging. Logging is to a file in comma-separated-values (.csv)
format. Set up logging in the LOG | SETUP menu. Logging may also be started /
stopped under the LOG menu. Data are captured each poll, set by the polling interval
in TOOLS | INTERFACE.

VIEW PLOT

Check this box to view a dynamic plot of data collected during polling. See

PLOTTING

for further information on configuring the plotter.

HW I/O

Check this box to force the Evaluation software to use the hardware pins CONV and
DRDY to initiate and monitor ADC conversion cycles, instead of sending commands to
the CONVERT_CTRL[CONV] register bit. Similarly, it is monitoring the FAULT and
ALERT hardware pin states to determine a FAULT and/or ALERT condition being
present. Note that in HW I/O mode, the REFRESH button toggles the hardware CONV
line, but the user may optionally use the CONVERT_CTRL[CONV] bit to force software
initiated conversions by clicking on the bit.

10

bq76PL536A and bq76PL536A-Q1 EVM Quick Start Guide

SLUU437D – October 2010 – Revised July 2015

Submit Documentation Feedback

Copyright © 2010–2015, Texas Instruments Incorporated

All manuals and user guides at all-guides.com

Summary of Contents for bq76PL536A

Page 1: ...ng the adapter for the first time The Aardvark driver should be installed prior to installing the TI supplied bq76PL536A and bq76PL536A Q1 Evaluation software 1 Download the USB Drivers Windows from t...

Page 2: ...ed to use the EVM with power supplies in place of cells see Use with 12 26 VDC Power Supply Connect cells to the supplied mating connectors with screw terminals BEFORE plugging the connector into the...

Page 3: ...he pin that will connect to the bottom most pin of the mating connector The positive connection is made to pin 7 the top most on the connector It is not necessary to connect to the intermediate pins d...

Page 4: ...ust remain isolated from earth ground EVM Assembly and Configuration www ti com Figure 1 Correct Connection of Three 20 V Power Supplies to bq76PL536EVM 3 Figure 2 Alternate Connection for a Single 54...

Page 5: ...sufficient current to ICs Base IC must be powered www ti com EVM Assembly and Configuration Figure 3 Incorrect Connections Base IC Not Powered Figure 4 Incorrect Connections Insufficient VBAT Per IC 5...

Page 6: ...rder from negative to positive in lieu of powering all three devices Due to poor termination of the unpowered devices in this configuration detailed testing or critical hardware evaluations should not...

Page 7: ...ack where lethal voltages may be present The galvanic isolation provided by the ISO COMMS section does not eliminate the need for safe handling procedures proper High Voltage equipment and protective...

Page 8: ...ICK The voltage measured by the bq76PL536A between the BATx and VSS pins VCELLn The voltage measured between the pair of pins VCn VCn 1 that is VCELL2 VC2 VC1 ADDR Displays the address of the device b...

Page 9: ...operation in circuit Some Group 3 registers are shown as registers at the bottom of the left side of the screen the others in the top right section of the screen as listboxes and registers 5 1 3 Quick...

Page 10: ...This list box allows choosing a polling rate between 100ms and 60s The LED illuminates green each time the GUI polls the device stack Useful as a heartbeat indicator when polling or logging is active...

Page 11: ...update The user hould see all cell voltages displayed along with registers showing FAULT and ALERT status DEVICE STATUS etc 5 3 Menus and Commands 5 3 1 File Menu This menu provides a way to save comp...

Page 12: ...RTS at startup Programmers wishing to check their code will want to disable most of these startup niceties during final code checkout See Packing List for details of the startup Options MEASUREMENT FI...

Page 13: ...itor Showing Communications Error 13 SLUU437D October 2010 Revised July 2015 bq76PL536A and bq76PL536A Q1 EVM Quick Start Guide Submit Documentation Feedback Copyright 2010 2015 Texas Instruments Inco...

Page 14: ...DISABLE CUV sets the CONFIG_CUV DISABLE bit disabling CUV ALERTs CLEAR LATCHED BITS clears all FAULT and ALERT bits latched in the FAULT and ALERT registers which may have otherwise normally been set...

Page 15: ...to the plot are not automatically captured in a log file The data are available for use or saving in a variety of formats while the program is running The plotted data are lost if the program is exit...

Page 16: ...This control allows zooming in or out on the displayed scale Choose this button then click and hold the left mouse button to operate Each data set VCn voltages VBRICK temperature time scale can be in...

Page 17: ...ers 025 post 0 10 cntr 8 1 ea CD ROM containing software and documentation Revision History Changes from B Revision May 2011 to D Revision Page Revision C was deprecated 1 Changed device from bq76PL53...

Page 18: ...tains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti co...

Page 19: ...to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasonable time to repair such EVM or provide...

Page 20: ...proved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not...

Page 21: ...some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sense resistors and heat si...

Page 22: ...ION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE LOSS OF DATA OR BUSINESS...

Page 23: ...e with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support tha...

Page 24: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ76PL536EVM 3 All manuals and user guides at all guides com...

Reviews: