![Texas Instruments BQ76942 Manual Download Page 8](http://html1.mh-extra.com/html/texas-instruments/bq76942/bq76942_manual_1095628008.webp)
7.1 Absolute Maximum Ratings (continued)
over operating free-air temperature range (unless otherwise noted)
DESCRIPTION
PINS
MIN
MAX
UNIT
Input voltage range, V
IN
VC1
maximum of
VSS–0.3 and
VC0–0.3
VSS+85
V
Input voltage range, V
IN
VC0
VSS–0.3
VSS+6
V
Output voltage range, V
O
CP1
V
BAT
–0.3
the minimum
of VSS+85 or
V
BAT
+15
V
Output voltage range, V
O
CHG
VSS–0.3
VSS+85
V
Output voltage range, V
O
DSG
VSS–0.3
VSS+85
V
Output voltage range, V
O
REG1, REG2, TS2 (for wakeup function), ALERT,
CFETOFF, DFETOFF, HDQ, DCHG, DDSG, when
configured to drive a digital output
VSS–0.3
VSS+6
V
Output voltage range, V
O
REG18
VSS–0.3
VSS+2
V
Maximum cell balancing current
through a single cell
VC0 – VC10
100
mA
Maximum VSS current, I
SS
75
mA
Functional temperature, T
FUNC
–40
85
°C
Junction temperature, T
J
–55
150
°C
Storage temperature, T
STG
–55
150
°C
(1)
Operation outside the
Absolute Maximum Ratings
may cause permanent device damage.
Absolute Maximum Ratings
do not imply
functional operation of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions
. If
outside the
Recommended Operating Conditions
but within the
Absolute Maximum Ratings
, the device may not be fully functional, and
this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2)
The current allowed to flow into the FUSE pin must be limited (such as by using external series resistance) to 2 mA or less.
(3)
When the ALERT, HDQ, CFETOFF, DFETOFF, DCHG, or DDSG pins are selected for thermistor input or general purpose ADC–input,
their voltage is limited to V
REG18
+ 0.3 V. These pins can accept up to 6 V when configured for other uses, such as a digital input.
7.2 ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/
JEDEC JS-001, all pins
±1000
V
V
(ESD)
Electrostatic discharge
Charged device model (CDM), per ANSI/ESDA/
JEDEC JS-002, all pins
±250
V
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
7.3 Recommended Operating Conditions
Typical values stated where T
A
= 25°C and V
BAT
= 55.0 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 55 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
BAT
Supply voltage
Voltage on BAT pin (normal
operation)
4.7
55
V
V
BAT
Voltage on BAT pin (OTP
programming)
10
12
V
T
OTP
OTP programming
temperature
–40
45
°C
V
PORA
Power-on reset
Rising threshold on BAT
3
4
V
V
PORA_HYS
Power-on reset hysteresis
Device shuts down when BAT <
V
PORA
- V
PORA_HYS
180
mV
SLUSE14B – DECEMBER 2020 – REVISED DECEMBER 2021
8
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links:
Summary of Contents for BQ76942