![Texas Instruments BQ769142 Manual Download Page 13](http://html1.mh-extra.com/html/texas-instruments/bq769142/bq769142_manual_1095400013.webp)
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG18
vs (V
REG18
at 25°C), I
REG18
= 1
mA, V
BAT
= 55 V
±0.15
%
ΔV
O(LINE)
Line regulation
ΔV
REG18
vs (V
REG18
at 25°C, V
BAT
= 55
V), I
REG18
= 1 mA, as V
BAT
varies across
specified range
–0.6
0.5
%
ΔV
O(LOAD)
Load regulation
ΔV
REG18
vs (V
REG18
, V
BAT
= 55 V), I
REG18
= 0 mA to 1 mA, at 25°C
–1.5
1.5
%
I
SC
Regulator short-circuit current limit
V
REG18
= 0 V
3
14
mA
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
(2)
Specified by design
7.11 REG0 Pre-regulator
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
BREG_HDRM
Pre-regulator control voltage
headroom ( min(V
BAT
- V
BREG
V
BAT
≥ 4.7 V
1.5
1.91
V
V
REGIN_INT
Pre-regulator voltage, when
generated using BREG
V
BAT
> 8 V, although specific requirement
depends on external device selected
5
5.5
5.8
V
V
REGIN_EXT
Pre-regulator voltage when using
externally supplied REGIN
See requirements based on settings of
REG1 and REG2
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REGIN
vs V
REGIN
at 25°C, I
REGIN
= 50
mA, V
BAT
> 8 V
±0.05
%
I
Max
Maximum current driven out from
BREG
Under short circuit conditions (V
REGIN
= 0
V)
2.5
3.33
mA
C
EXT
External capacitor REGIN to VSS
15
22
27
nF
C
BREG
External capacitor BREG to VSS
150
pF
(1)
Operation with V
BAT
up to 80 V is supported when the charge pump is not in operation. Whenever the charge pump is in operation (in
5.5 V or 11 V mode), the maximum voltage on V
BAT
should be reduced to ensure the voltage on CP1, CHG, and DSG does not exceed
their maximum specified voltage.
(2)
Supported output current is limited for V
STACK
< 5.5 V. V
REGIN
limited to ~2.5 V below V
BAT
.
(3)
Capacitance should be above 7 nF after consideration for aging and derating.
(4)
Specified by design
7.12 REG1 LDO
Typical values stated where T
A
= 25°C and V
BAT
= 59.2 V, min/max values stated where T
A
= -40°C to 85°C and V
BAT
= 4.7 V
to 80 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
REG1_1.8
Regulator voltage (nominal 1.8V setting)
V
REGIN
≥ 3.0 V, I
REG1
= 0 mA to 45 mA
1.6
1.84
2
V
V
REG1_2.5
Regulator voltage (nominal 2.5V setting)
V
REGIN
≥ 3.5 V, I
REG1
= 0 mA to 45 mA
2.25
2.55
2.75
V
V
REG1_3.0
Regulator voltage (nominal 3.0V setting)
V
REGIN
≥ 3.8 V, I
REG1
= 0 mA to 45 mA
2.7
3.05
3.3
V
V
REG1_3.3
Regulator voltage (nominal 3.3V setting)
V
REGIN
≥ 4.1 V, I
REG1
= 0 mA to 45 mA
3
3.36
3.6
V
V
REG1_5.0
Regulator voltage (nominal 5.0V setting)
V
REGIN
≥ 5.0 V, I
REG1
= 0 mA to 45 mA
4.5
5.19
5.5
V
ΔV
O(TEMP)
Regulator output over temperature
ΔV
REG1
vs (V
REG1
at 25°C, I
REG1
= 20
mA, V
REGIN
= 5.5 V, V
REG1
set to
nominal 3.3 V setting)
±0.25
%
SLUSE91A – SEPTEMBER 2020 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated
13
Product Folder Links:
Summary of Contents for BQ769142