3.7 Advanced Comm I2C Screen
Press the
Advanced Comm I2C
button to select the Advanced I2C Comm window. This tool provides access to
parameters using I2C and Manufacturing Access commands (see
Figure 3-7. Advanced Comm Screen
3.7.1 Examples
Reading Standard Data Commands.
• Read SBData Voltage (0x08)
– Start Register = 0x08
– Number of Bytes to Read = 2
– Press the
Read
button
– Date returned =8C 3C, which a byte swapped
– 0x3C8C = 15500mV, when converted to decimal
Sending a MAC Gauging() to enable IT via ManufacturerAccess().
• With Impedance Track™ disabled, send Gauging() (0x0021) to ManufacturerAccess().
– Start Register = 0x00
– Bytes to Write = 21 00
– Press the Write button
– The QEN flag should set in the Control Status register to indicate that Impedance Track is enabled
Battery Management Studio
SLUU904B – APRIL 2012 – REVISED APRIL 2021
bq34z100EVM Wide Range Impedance Track™ Enabled Battery Fuel Gauge
Solution
13
Copyright © 2021 Texas Instruments Incorporated