Battery Management Studio
3
Battery Management Studio
3.1
Registers Screen
Apply power to the EVM after you have completed the EVM Connections section. Run Battery
Management Studio from the Start | Programs | Texas Instruments | Battery Management Studio menu
sequence, or the Battery Management Studio shortcut. The Registers screen (see
) appears. The
Registers
section contains parameters used to monitor gauging. The
Bit Registers
section provides a bit-
level picture of status and fault registers. A green flag indicates that the bit is 0 (low state) and a red flag
indicates that the bit is 1 (high state). Data begins to appear once the
Refresh
(single-time scan) button is
selected, or it scans continuously, if the
Scan
button is selected.
Figure 2. Registers Screen
The continuous scanning period can be set via the | Window | Preferences | SBS | Scan Interval | menu
selection.
The Battery Management Studio program provides a logging function which logs the values selected by
the
Log
check boxes located beside each parameter in the
Registers
section. To enable this function,
select the
Log
button; this causes the
Scan
button to be selected. When logging is stopped, the
Scan
button is still selected and has to be manually deselected.
6
bq34z100EVM Wide Range Impedance Track™ Enabled Battery Fuel Gauge
SLUU904A – April 2012 – Revised February 2015
Solution
Copyright © 2012–2015, Texas Instruments Incorporated