Hardware Connection
Figure 9. bq30z554 Circuit Module Connection to Cells and System Load/Charger
7.2
PC Interface Connection
To configure the hardware to interface to the PC, do the following:
1. Connect the bq30z554 device-based smart battery to the EV2300 or EV2400 using the provided cable
or the connections shown in
Table 4. Circuit Module to EV2300 or EV2400 Connections
bq30z554 Device-Based Battery
EV2300 or EV2400
SMBD
SMBD
SMBC
SMBC
VSS
GND
2. Connect the PC USB cable to the EV2300 or EV2400 and the PC USB port.
The bq30z554EVM-001 is now set up for operation.
11
SLUUA36 – November 2012
bq30z554EVM SBS 1.1 Impedance Track™ Enabled Battery Management
Solution EVM