Battery Management Studio
13
SLUUBP4 – June 2017
Copyright © 2017, Texas Instruments Incorporated
bq27750EVM 1-Series Li-Ion Battery Pack Manager Evaluation Module
3.8
Advanced Comm Screen
Press the
Advanced Comm
button to select the
Advanced Comm
window. This tool provides access to
parameters using I
2
C and Manufacturing Access commands, see
. The transaction log screen
shows the history of sent commands.
NOTE:
I
2
C commands are sent in Little-Endian format.
Figure 9. Advanced Comm Screen
Examples:
Reading an I
2
C Command.
•
Read chemical ID (0x 0006).
–
Write to mac address 3e Command 06 00 (see
)
–
Read 4 bytes.
–
The result returned is 10 12, which is little endian for chem id 1210.
Sending a MAC
Gauging()
to enable IT via
ManufacturerAccess()
.
•
With Impedance Track™ disabled, send
Gauging()
(0x0021) to
ManufacturerAccess()
.
–
Write to mac address 3e command 21 00 (see