3.3
Calibration
The bq27220EVM must be calibrated to ensure accurate value reporting. Calibrate the EVM in the
Calibration
window in bqStudio (
Figure 4. Calibration Screen
Calibration consists of the following:
•
CC Offset/Board Offset: Check
Calibrate CC Offset
and
Calibrate Board Offset
, then click the
Calibrate Gas Gauge
button to calibrate the Coulomb counter and board offsets. Ensure no current is
flowing through the sense resistor during these steps. After a successful calibration, a green check
mark shows next to the
Calibrate Gas Gauge
button.
•
Current: Connect a 2-A load to LOAD+/LOAD– or a current source to LOAD–/PACK–. Ensure the
measured current reported is negative, or else reverse the connections. Check
Calibrate Current
and
enter the current into the textbox then click the
Calibrate Gas Gauge
button.
•
Voltage: Apply a known DC voltage to PACK+/PACK– with no current flowing through the sense
resistor. Check
Calibrate Voltage
and enter the voltage into the textbox then click the
Calibrate Gas
Gauge
button.