2 Test Summary

This section describes the jumpers and connectors on the EVM as well as how to properly connect, setup, and 
use the BQ25172EVM.

2.1 Equipment

This section includes a list of supplies required to perform tests on this EVM.

1. Battery simulator such as Keithley 2400 or equilvalent. A real NiMH battery may also be used.
2. Power supply, 5V 1A input. Note that unit can operate up to 6.6V input.
3. Voltage meter and current meter.

2.2 Cautions

To prevent possible damage to battery under test verify that charging conditions of the cell are not exceeded. 
Check max charge voltage and current.

Power dissipation of the device can be exceeded with too high an input to output voltage drop and current. 
Thermal regulation begins reducing current at 125 °C, at 150 °C device will shut off.

Device can get hot during high input-to-output voltage drop and high current conditions. Use caution when 
handling the board.

2.3 Test Instructions

In order for this EVM to operate properly, the following components must be connected and properly configured.

1. Set input power supply to 5V and Battery Simulator to 2.2V with compliance to support 800mA. Turn off 

Supply and Battery Simulator.

2. Connect input voltages to J1 and Battery Simulator to J2 on the EVM.
3. Configure all EVM jumpers to factory setting, refer to table below.
4. Turn on all supplies and loads

a. 5V Input supply current limit should be greater than 500mA
b. Out voltage should be 2.2V and charge current 400mA

5. Simulate battery completing charge by increasing Battery Simulator voltage to 2.4V

a. Current will decrease to 0mA

Table 2-1. Jumper Factory Setting

I/O Connector

Factory Setting

JP1

Installed

JP2

IN

JP3

Installed

JP4

Fixed

JP5

Installed

JP6

Fixed

JP7

N/A

JP8

N/A

JP9

N/A

S1

Position 1

S2

N/A

Note: IN, ON, Fixed are positions of a 3 pin header. If it is a 2 pin header then it is installed or not installed.

www.ti.com

Test Summary

SLUUCO1 – JULY 2022

Submit Document Feedback

BQ25172EVM Evaluation Module

3

Copyright © 2022 Texas Instruments Incorporated

Summary of Contents for BQ25172EVM

Page 1: ...e noted Table of Contents 1 Introduction 2 1 1 Printed Circuit Board Assembly 2 1 2 I O Descriptions 2 2 Test Summary 3 2 1 Equipment 3 2 2 Cautions 3 2 3 Test Instructions 3 3 Board Layout Schematic...

Page 2: ...OUT BAT GND BAT GND TS Battery connection TS should be 10k NTC but not needed JP1 VSET ADJ Disable R9 default is installed JP2 REG IN OUT Source voltage for housekeeping regulator U2 Default Input vo...

Page 3: ...ard 2 3 Test Instructions In order for this EVM to operate properly the following components must be connected and properly configured 1 Set input power supply to 5V and Battery Simulator to 2 2V with...

Page 4: ...oard layout is shown in Figure 3 1 to Figure 3 6 Figure 3 1 Top Overlay Figure 3 2 Top Solder Board Layout Schematic and Bill of Materials www ti com 4 BQ25172EVM Evaluation Module SLUUCO1 JULY 2022 S...

Page 5: ...Top Layer Figure 3 4 Bottom Layer www ti com Board Layout Schematic and Bill of Materials SLUUCO1 JULY 2022 Submit Document Feedback BQ25172EVM Evaluation Module 5 Copyright 2022 Texas Instruments In...

Page 6: ...ttom Solder Figure 3 6 Bottom Overlay Board Layout Schematic and Bill of Materials www ti com 6 BQ25172EVM Evaluation Module SLUUCO1 JULY 2022 Submit Document Feedback Copyright 2022 Texas Instruments...

Page 7: ...tic is shown in Figure 3 7 Figure 3 7 BQ25172EVM Schematic www ti com Board Layout Schematic and Bill of Materials SLUUCO1 JULY 2022 Submit Document Feedback BQ25172EVM Evaluation Module 7 Copyright 2...

Page 8: ...JP1 JP3 JP5 JP7 4 Sullins Connector Solutions Header 100mil 2x1 Tin TH Header 2 PIN 100mil Tin PEC02SAAN Sullins Connector Solutions JP2 JP4 JP6 3 Sullins Connector Solutions Header 100mil 3x1 Tin TH...

Page 9: ...EC Q200 Grade 0 0603 0603 CRCW060310K0FKEA Vishay Dale R21 1 Vishay Dale 301 RES 301 1 0 1 W AEC Q200 Grade 0 0603 0603 CRCW0603301RFKEA Vishay Dale R24 1 Yageo 1 00k RES 1 00 k 1 0 1 W 0603 0603 RC06...

Page 10: ...FID1 FID2 FID3 0 N A Fiducial mark There is nothing to buy or mount N A N A N A JP8 JP9 0 Sullins Connector Solutions Header 100mil 3x1 Tin TH Header 3 PIN 100mil Tin PEC03SAAN Sullins Connector Solut...

Page 11: ...or Alternate Manufacturer columns all parts may be substituted with equivalents www ti com Board Layout Schematic and Bill of Materials SLUUCO1 JULY 2022 Submit Document Feedback BQ25172EVM Evaluatio...

Page 12: ...isions may differ from page numbers in the current version DATE REVISION NOTES July 2022 Initial Release Revision History www ti com 12 BQ25172EVM Evaluation Module SLUUCO1 JULY 2022 Submit Document F...

Page 13: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 14: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 15: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 16: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 17: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 18: ...change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of thes...

Reviews: