9.5.1.49 TS_COLD Register (Address = 0x62) [reset = 0x7C]
TS_COLD is shown in
and described in
Return to
.
Figure 9-64. TS_COLD Register
7
6
5
4
3
2
1
0
TS_COLD_7:0
R/W-8b01111100
Table 9-58. TS_COLD Register Field Descriptions
Bit
Field
Type
Reset
Description
7-0
TS_COLD_7:0
R/W
8b01111100 TS Cold Threshold
1b = 4.688 mV
10b = 9.375 mV
100b = 18.75 mV
1000b = 37.5 mV
10000b = 75 mV
100000b = 150 mV
1000000b = 300 mV
10000000b = 600 mV