![Texas Instruments BQ25157 Manual Download Page 46](http://html1.mh-extra.com/html/texas-instruments/bq25157/bq25157_manual_1094297046.webp)
9.5.1.6 FLAG2 Register (Address = 0x5) [reset = 0x0]
.
Return to
.
Clear on Read
Figure 9-21. FLAG2 Register
7
6
5
4
3
2
1
0
ADC_READY_
FLAG
COMP1_ALAR
M_FLAG
COMP2_ALAR
M_FLAG
COMP3_ALAR
M_FLAG
RESERVED
TS_OPEN_FLA
G
RC-1b0
RC-1b0
RC-1b0
RC-1b0
RC-3b000
RC-1b0
Table 9-15. FLAG2 Register Field Descriptions
Bit
Field
Type
Reset
Description
7
ADC_READY_FLAG
RC
1b0
ADC Ready Flag
1b0 = No ADC conversion completed since last flag read
1b1 = ADC Conversion Completed
6
COMP1_ALARM_FLAG
RC
1b0
ADC COMP1 Threshold Flag
1b0 = No threshold crossing detected
1b1 = Selected ADC measurement crossed condition set by
1_ADCALARM_ABOVE bit
5
COMP2_ALARM_FLAG
RC
1b0
ADC COMP2 Threshold Flag
1b0 = No threshold crossing detected
1b1 = Selected ADC measurement crossed condition set by
2_ADCALARM_ABOVE bit
4
COMP3_ALARM_FLAG
RC
1b0
ADC COMP3 Threshold Flag
1b0 = No threshold crossing detected
1b1 = Selected ADC measurement crossed condition set by
3_ADCALARM_ABOVE bit
3-1
RESERVED
RC
3b000
Reserved
0
TS_OPEN_FLAG
RC
1b0
TS Open Flag
1b0 = No TS Open fault detected
1b1 = TS Open fault detected