Introduction
5
SLUUBC8A – August 2015 – Revised May 2016
Copyright © 2015–2016, Texas Instruments Incorporated
bq2512x Evaluation Module
1.5
Test Points
provides descriptions of the test points.
Table 2. Test Points Description
Test Points
Description
TP1
TS pin
TP2
SDA pin
TP3
/MR pin
TP4
SCL pin
TP5
INT pin
TP6
/PG pin
TP7
/RESET pin
TP8
BAT pin
TP9
LS/LDO pin
TP10
SYS pin
TP11
PMID pin
TP13
IN pin
TP14
SW pin
TP /CD
/CD pin
1.6
Default Settings
The bq2512xEVM module has provided the capability of changing key parameters using I
2
C and the
EV2400 communication interface. However, I
2
C communication is not required for this device to operate.
The module is programmed to the default settings as is described in
shows the initial
jumper positions on the PCB.
Table 3. Default Settings
Parameter
Options
bq2512x
BAT_UVLO
2.2 V to 3.4 V (200-mV step)
3.0 V
VSYS
1.1 V to 3.3 V (100-mV step)
1.8 V
LS/LDO
LS, 0.8 V to 3.3 V (100-mV step)
LS
VBREG
3.6 V to 4.65 V (10-mV step)
4.2 V
ICHG
5 mA to 300 mA
10 mA
IPRETERM
500 µA to 50 mA
2 mA
Input ILIM
50 mA to 400 mA (50-mA step)
100 mA
VIN_DPM_ON
On or Off
On
VIN_DPM Threshold
4.2 V to 4.9 V
4.6 V
Auto Charge
On or Off
On
Safety Timer
30 min, 3 hr, 9 hr, Disabled
3 hr
Table 4. Initial Jumper Position
J6
J9
J11
J12
J14
J15
J25
TS = TS_Pot
ITERM = GND
ISET= GND
Installed
ILIM = GND
Installed
VINLS = PMID