Introduction
6
SLUUBC8A – August 2015 – Revised May 2016
Copyright © 2015–2016, Texas Instruments Incorporated
bq2512x Evaluation Module
1.7
Recommended Operating Conditions
The recommended operating conditions are shown in
.
(1)
Any voltage greater than shown should be a transient event.
(2)
These inputs will support 6.6 V for less than 10% of the lifetime at V
(BAT)
or V
IN
, with a reduced current and/or performance.
Table 5. Recommended Operating Conditions
(1) (2)
MIN
NOM
MAX
Unit
V
IN
IN voltage range
3.4
5
20
V
IN operating voltage range, recommended
3.4
5
5.5
V
BAT
VBAT operating voltage range
5.5(1)
V
V
VINLS
VINLS voltage range for Load Switch
0.8
5.5(2)
V
V
VINLS
VINLS voltage range for LDO
2.2
5.5
V
I
IN
Input Current, IN input
400
mA
I
SW
Output Current from SW, DC
300
mA
I
PMID
Output Current from PMID, DC
300
mA
I
LS/LDO
Output Current from LS/LDO
100
mA
I
BAT
, I
SYS
Charging and discharging using internal battery FET
300
mA
T
J
Operating junction temperature range
-40
125
°C
2
Test Summary
This section describes the test configuration of the bq2512xEVM evaluation module for bench evaluation.
2.1
Recommended Test Equipment
2.1.1
Power Supplies
1. Power Supply #1 (PS#1): a power supply capable of supplying 5 V at 1 A is required.
2. Power Supply #2 (PS#2): a power supply capable of supplying 5 V at 1 A is required.
2.1.2
Load
Testing with an actual battery is the best way to verify operation in the system. If a battery is unavailable,
then a source meter like a Keithley 2420, capable of both sourcing and sinking current, or a circuit similar
to the one shown in
can simulate a battery when connected to PS#2.
Figure 2. BAT Load (PR1010) Schematic