Texas Instruments bq24195/L User Manual Download Page 21

FCC Interference Statement for Class B EVM devices

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

For EVMs annotated as IC – INDUSTRY CANADA Compliant

This Class A or B digital apparatus complies with Canadian ICES-003.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.

Concerning EVMs including radio transmitters

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.

Concerning EVMs including detachable antennas

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.

Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.

Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de
l'utilisateur pour actionner l'équipement.

Concernant les EVMs avec appareils radio

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

Concernant les EVMs avec antennes détachables

Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain
maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.

Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel
d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans
cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

Summary of Contents for bq24195/L

Page 1: ...ow of the bq24195x Evaluation Software for bq24195 L 6 4 CHG Mode Ripple and Duty Cycle VBUS 5 V VBAT 3 7 V 8 5 Boost Mode Ripple and Duty Cycle VBAT 3 7 V 9 6 bq24195 L EVM Top Layer 11 7 bq24195 L E...

Page 2: ...a Thevinen equivalent drive of 72k and for Q2 OTG ckt is 35k allowing the OTG signal to be pulled low disables Boost Mode prior to the input voltage being applied 1 3 General Descriptions The bq24195...

Page 3: ...VM Table 3 Recommended Operating Conditions Symbol Description MIN TYP MAX Unit Supply voltage VIN Input voltage from AC adapter input 3 9 5 12 6 V Battery voltage VBAT Voltage applied at VBAT termina...

Page 4: ...rt and a USB cable The bq2419xEVM evaluation software must be properly installed 2 1 6 USB to GPIO Communication Kit HPA172 USB Interface Adapter 2 1 7 Software Unzip the bq2419xEVM_GUI zip and double...

Page 5: ...5 V Turn off disable Load Connect Load in series with a current meter multimeter ground side to J2 BAT and GND as shown in Figure 2 5 Connect a voltage meter across J2 BAT and GND 6 Connect the HPA17...

Page 6: ...ETUP steps are followed ILIM Setting Set the potentiometer to its lowest value for max input current by connecting an ohm meter between point TP9 and ground Turn the screw on the potentiometer counter...

Page 7: ...Voltage Limit to 4 208 V 7 Set Fast Charge Current ICHG to 512 mA 8 Set Pre Charge Current to 256 mA 9 Deselect Enable Termination see the following image 10 Click the Read button twice Observe Everyt...

Page 8: ...N 500 mA 200 mA 2 3 2 5 Verify Scope Measurements See Figure 4 500 ns div C1 AC coupled 20 mV div Vac_PMID TP20 to GND Ripple excluding high frequency spikes 10 mV C2 5 V div Vdc_SW TP2 Frequency betw...

Page 9: ...rop down window 6 Verify VPMID to GND on J5 is between 4 9 V and 5 3 V 7 Verify scope measurement Figure 5 C1 AC coupled 20 mV div Vac_PMID TP20 to GND Ripple excluding high frequency spikes C2 5 V di...

Page 10: ...with a short copper trace connection or GND plane 4 Route analog ground separately from power ground Connect analog ground and connect power ground separately Connect analog ground and power ground t...

Page 11: ...ic and Bill of Materials 4 1 Board Layout Figure 6 through Figure 11 illustrate the board layouts for this EVM Figure 6 bq24195 L EVM Top Layer 11 SLUUA18 October 2012 bq24195 L EVM PWR193 User s Guid...

Page 12: ...Schematic and Bill of Materials www ti com Figure 7 bq24195 L EVM Second Layer 12 bq24195 L EVM PWR193 User s Guide SLUUA18 October 2012 Submit Documentation Feedback Copyright 2012 Texas Instruments...

Page 13: ...oard Layout Schematic and Bill of Materials Figure 8 bq24195 L EVM Third Layer 13 SLUUA18 October 2012 bq24195 L EVM PWR193 User s Guide Submit Documentation Feedback Copyright 2012 Texas Instruments...

Page 14: ...Schematic and Bill of Materials www ti com Figure 9 bq24195 L EVM Bottom Layer 14 bq24195 L EVM PWR193 User s Guide SLUUA18 October 2012 Submit Documentation Feedback Copyright 2012 Texas Instruments...

Page 15: ...ard Layout Schematic and Bill of Materials Figure 10 bq24195 L EVM Top Assembly 15 SLUUA18 October 2012 bq24195 L EVM PWR193 User s Guide Submit Documentation Feedback Copyright 2012 Texas Instruments...

Page 16: ...hematic and Bill of Materials www ti com Figure 11 bq24195 L EVM Bottom Assembly 16 bq24195 L EVM PWR193 User s Guide SLUUA18 October 2012 Submit Documentation Feedback Copyright 2012 Texas Instrument...

Page 17: ...3 4 5 6 7 8 9 10 J3 R23 R6 R11 10 0k JP4 R4 200 JP6 JP3 R24 768 R15 10 0k C13 R1 0 R2 0 C15 10uF J7 C3 C12 C16 10uF C17 C18 TP19 L1 2 2uH JP1 3 1 2 5 6 7 4 8 Q1 CSD25302Q2 R16 10 0k R5 100k R17 10 0k...

Page 18: ...54 0 307 in A USB B M5 9 9 JP1 JP2 JP3 PEC02SAAN Header Male 2 pin 100mil spacing 0 100 in 2 PEC02SAAN Sullins JP4 JP5 JP6 JP7 JP8 JP9 1 1 L1 2 2 H Inductor SMT 5 A 37 m 0 204 0 216 in IHLP2020BZER2R2...

Page 19: ...0 044 0 20 in SJ 5303 3M Notes 1 These assemblies are ESD sensitive observe ESD precautions 2 These assemblies must be clean and free from flux and all contaminants Use of no clean flux is not accept...

Page 20: ...ncy energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES 003 rules which are designed to provide reasonable protection against radio fr...

Page 21: ...na type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved...

Page 22: ...roduct only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product or 3 Use of this product only after you obtained the Technical Regulatio...

Page 23: ...property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and in...

Page 24: ...egulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided...

Reviews: