To
Computer
USB port
USB
Interface
Adapter
I/O
USB
T
exasInstruments
©2006
10-pin
Ribbon
Cable
To EVM
Test Summary
www.ti.com
2.2.7
SOFTWARE
For -001, -002, -003, -004, -005 unzip BQ2415xSetup.zip and double click on the “SETUP.EXE” file.
Follow the installation steps.
For -006, -007, -008 unzip BQ24153_6_8Setup.zip and double click on the “SETUP.EXE” file. Follow the
installation steps.
2.3
Equipment Setup
(A) Set the power supply #1 for 5V ± 100mV DC, 2.0 ± 0.1A current limit and then turn off supply.
(B) Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (DC+, DC–).
(C) Connect a voltage meter across J1 (DC+, DC–).
(D) Connect the Load #2 in series with a current meter (multimeter) to J2 (BAT+, BAT–). Make sure a
voltage meter is connected across J2 (BAT+, BAT–). Turn on the Load #2. Use the constant voltage
mode. Set the output voltage to 2.5V.
(E) Turn off Load #2.
(F) Connect J5 to HPA172 kit by 10-pin ribbon cable. Connect the USB port of the HPA172 kit to the USB
port of the computer. The connections are shown in
Figure 1. Connections of the HPA172 Kit
(G) Installed jumpers per
Table 1. Factory Jumper Settings
Spin
JMP1
JMP2
JMP3
JMP4
JMP5
HPA256-001
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24150)
HPA256-002
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24151)
HPA256-003
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24152)
HPA256-004
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24150A)
HPA256-005
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24151A)
HPA256-006
(-LED-) ON
(-LO-) ON
OFF
(-LO-) ON
ON
(bq24153)
HPA256-007
(-LED-) ON
(-HI-) ON
OFF
(-LO-) ON
ON
(bq24156)
HPA256-008
(-LED-) ON
(-LO-) ON
OFF
(-LO-) ON
ON
(bq24158)
4
bq2415x YFF EVM
SLUU321B – June 2008 – Revised May 2010
Copyright © 2008–2010, Texas Instruments Incorporated