Texas Instruments bq2415 Series User Manual Download Page 13

Evaluation Board/Kit Important Notice

Texas Instruments (TI) provides the enclosed product(s) under the following conditions:

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY 
and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the
product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are
not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations,
including product safety and environmental measures typically found in end products that incorporate such semiconductor
components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding
electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the
technical requirements of these directives or other related directives.

Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30
days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY
SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all
claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to
take any and all appropriate precautions with regard to electrostatic discharge.

EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.

TI assumes no liability for applications assistance, customer product design, software performance, or infringement of
patents or services described herein.

Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the
product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s
environmental and/or safety programs, please contact the TI application engineer or visit

www.ti.com/esh

.

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.

FCC Warning

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY 
and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and
can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15
of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this
equipment in other environments may cause interference with radio communications, in which case the user at his own expense
will be required to take whatever measures may be required to correct this interference.

EVM Warnings and Restrictions

It is important to operate this EVM within the input voltage range of 4 V to 6 V and the output voltage range of 0 V to 4.44 V .

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are
questions concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the
EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load
specification, please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than 65°C. The EVM is designed to
operate properly with certain components above 125°C as long as the input and output ranges are maintained. These components
include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of
devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near
these devices during operation, please be aware that these devices may be very warm to the touch.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2010, Texas Instruments Incorporated

Summary of Contents for bq2415 Series

Page 1: ...q2415x EVM 5 3 The Main Window of the bq2415x Evaluation Software For bq24150 1 2 0A 1A 5 4 The Main Window of the bq24153_6_8 Evaluation Software for bq24153 6 8 6 5 Test setup for HPA256 7 6 Top Layer 10 7 Bottom Layer 10 8 Top Assembly 11 9 Top Silk 11 List of Tables 1 Factory Jumper Settings 4 1 Introduction 1 1 EVM Features Evaluation Module For BQ2415x High Efficiency Fully Integrated NMOS N...

Page 2: ... positive output connect to CSOUT pin J3 SCL I2 C clock connect to SCL pin J3 SDA I2 C data connect to SDA pin J3 DC AC adapter or USB negative output J4 STAT Status output can be connected to STAT pin by JMP1 set to EXT 2 3 J4 OTG SLRST Connect to OTG SLRST pin J4 DC AC adapter or USB negative output 1 4 Control and Key Parameters Setting Jack Description Factory Setting LED 1 2 Connect STAT pin ...

Page 3: ... shorted Measure A B Check specified parameters A B If measured values are not within specified limits the unit under test has failed Observe A B Observe if A B occur If they do not occur the unit under test has failed Assembly drawings have location for jumpers test points and individual components 2 2 Equipment 2 2 1 POWER SUPPLIES Power Supply 1 PS 1 a power supply capable of supplying 5 V at 2...

Page 4: ... sure a voltage meter is connected across J2 BAT BAT Turn on the Load 2 Use the constant voltage mode Set the output voltage to 2 5V E Turn off Load 2 F Connect J5 to HPA172 kit by 10 pin ribbon cable Connect the USB port of the HPA172 kit to the USB port of the computer The connections are shown in Figure 1 Figure 1 Connections of the HPA172 Kit G Installed jumpers per Table 1 Table 1 Factory Jum...

Page 5: ... Setup for HPA256 bq2415x EVM I Turn on the computer For 001 002 003 004 005 open the bq2415x evaluation software The main window of the software is shown in Figure 3 For 006 007 008 open the bq24153_6_8 evaluation software Select part number bq24153 bq24156 and bq24158 and click GO button The main window of the software is show in Figure 4 Figure 3 The Main Window of the bq2415x Evaluation Softwa...

Page 6: ... 4 20V For 006 007 008 Make sure Immediate Updates is enabled Check Periodic Resets set Rate to 5 seconds Check Periodic Reads set Rate to 1 second Make sure Operation Mode is Charger Mode Uncheck Charge Current Termination Check STAT Pin Select Charge Current Sense Voltage to Normal Select Battery Regulation Voltage to 4 20V Measure V J2 VBAT VBAT 4 2 100mV Observe D1 is on 3 Enable Load 2 Measur...

Page 7: ...r layout to minimize high frequency current path loop is critical 3 The sense resistor should be adjacent to the junction of the inductor and output capacitor Route the sense leads connected across the RSNS back to the IC close to each other minimize loop area or on top of each other on adjacent layers do not route the sense leads through a high current path 4 Place all decoupling capacitor close ...

Page 8: ... 1 1 D2 BAT54C Diode Dual Schottky SOT23 BAT54C Vishay Liteon 200 mA 30 V 1 1 1 1 1 1 1 1 J1 ED1514 2DS Terminal Block 2 pin 0 27 x 0 25 inch ED1514 2DS OST 6 A 3 5mm 3 3 3 3 3 3 3 3 J2 J3 J4 ED1515 3DS Terminal Block 3 pin 0 41 x 0 25 inch ED1515 3DS OST 6 A 3 5mm 1 1 1 1 1 1 1 1 J5 2510 Connector Male 0 338 x 0 788 2510 6002UB 3M 6002UB Straight 2x5 pin 100mil inch spacing 4 Wall 3 3 3 3 3 3 3 3...

Page 9: ...Polymer Battery 0 0 1 0 0 0 0 0 U1 BQ24152YF IC Battery Charger for WCSP BQ24152YFF TI F Single Cell Li Ion and Li Polymer Battery 0 0 0 1 0 0 0 0 U1 BQ24150AY IC Battery Charger for WCSP BQ24150AYFF TI FF Single Cell Li Ion and Li Polymer Battery 0 0 0 0 1 0 0 0 U1 BQ24151AY IC Battery Charger for WCSP BQ24151AYFF TI FF Single Cell Li Ion and Li Polymer Battery 0 0 0 0 0 1 0 0 U1 BQ24153YF IC Bat...

Page 10: ...aterials Board Layout and Schematics www ti com 4 2 Board Layout Figure 6 Top Layer Figure 7 Bottom Layer 10 bq2415x YFF EVM SLUU321B June 2008 Revised May 2010 Copyright 2008 2010 Texas Instruments Incorporated ...

Page 11: ...www ti com Bill of Materials Board Layout and Schematics Figure 8 Top Assembly Figure 9 Top Silk 11 SLUU321B June 2008 Revised May 2010 bq2415x YFF EVM Copyright 2008 2010 Texas Instruments Incorporated ...

Page 12: ...Bill of Materials Board Layout and Schematics www ti com 4 3 Schematic 12 bq2415x YFF EVM SLUU321B June 2008 Revised May 2010 Copyright 2008 2010 Texas Instruments Incorporated ...

Page 13: ...oduct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti com esh No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine process or combination in which such TI products ...

Page 14: ...ch statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necessary expertise in the safety and regulatory ramifications o...

Reviews: