Texas Instruments BQ20Z40EVM-001 User Manual Download Page 13

9

Calibration Screen

9.1

How to Calibrate

9.2

To Calibrate the bq20z40

9.3

Board Offset Calibration

9.4

Pack Voltage Calibration

www.ti.com

Calibration Screen

The bq20z40 must be calibrated using power supplies or a power supply and cell simulation resistors (200

to 1000

each) before cells are attached. Before the bq20z40 is calibrated:

Connect and measure a 2-A current source from 1N (-) and Pack- (+) to calibrate without using the
FETs (calibration using the FETs is not recommended).

Measure the pack voltage from Batt+ to Batt- (total of cell voltages).

Measure the temperature of the pack.

Whether the foregoing steps are necessary depends on the type of calibration being performed.

Select the types of calibration to be performed.

Enter the measured values for the types selected (Except for

CC Offset Calibration

).

If

Voltage Calibration

is selected, enter the number of cells on the pack.

If

Temperature Calibration

is selected, select the sensor that is to be calibrated.

If the current source is connected between 1N and Pack-, then select the

Off (Bypassed)

check box in the

FET Control

section.

Press the

Calibrate Part

button.

This performs the offset calibration for the current offset of the board.

Remove any current source, load, or external voltage from the PACK terminals.

Press the

Software Board Offset Calibration

button.

This calibrates the voltage at the AFE Pack pin.

Ensure that

Voltage Calibration

has been performed for the pack. If

Voltage Calibration

is not performed,

then

Pack Voltage Calibration

calibrates incorrectly.

Remove load/external voltage applied between Pack+ and Pack-.

Press the

Pack Voltage

button to calibrate.

SLUU320C – January 2009 – Revised June 2009

bq20z40EVM-001 SBS 1.1 Impedance Track™Technology

13

Enabled Battery Management Solution EVM

Submit Documentation Feedback

Summary of Contents for BQ20Z40EVM-001

Page 1: ...of the bq20z40 bq29330 bq29412 solution under different charge and discharge conditions Contents 1 Features 2 2 bq20z40 bq29330 Based Circuit Module 2 3 bq20z40 bq29330 Circuit Module Schematic 3 4 Ci...

Page 2: ...ll Any The bq20z40 bq29330 bq29412 based circuit module is a complete and compact example solution of a bq20z40 and bq29330 circuit for battery management and protection of Li ion or Li polymer packs...

Page 3: ...arge current path in order to sustain sufficient Pack voltage when the battery voltage is too low to power up the bq29330 IC If the charger has a precharge function R12 and FET Q2 are not used The EVM...

Page 4: ...ons PCB layers and assembly drawing for the bq20z40 bq29330 module Figure 1 bq20z40EVM 001 Layout Silk Screen Figure 2 Top Assembly Figure 3 Top Layer 4 bq20z40EVM 001 SBS 1 1 Impedance Track Technolo...

Page 5: ...youts and Bill of Materials Figure 4 Bottom Layer Figure 5 Bottom Assembly SLUU320C January 2009 Revised June 2009 bq20z40EVM 001 SBS 1 1 Impedance Track Technology 5 Enabled Battery Management Soluti...

Page 6: ...86 3 R13 R15 5 1K Resistor chip 5 1 k 1 16 W 5 0603 STD STD R18 3 R14 R25 1M Resistor chip 1 M 1 16 W 5 0603 STD STD R30 1 R16 100K Resistor chip 100 k 1 16 W 5 0603 STD STD 1 R17 0 010 75ppm Resistor...

Page 7: ...le Physical Layouts and Bill of Materials Figure 6 Schematic SLUU320C January 2009 Revised June 2009 bq20z40EVM 001 SBS 1 1 Impedance Track Technology 7 Enabled Battery Management Solution EVM Submit...

Page 8: ...tory Open the archive containing the installation package and copy its contents in a temporary directory The executable filename can consist of several component names and versions Double click on the...

Page 9: ...rge test connect SYS PRES pin to PACK pin to set SYS PRES state To test sleep mode disconnect the SYS PRES pin Figure 7 bq20z40 bq29330 Circuit Module Connection to Cells and System Load Charger The f...

Page 10: ...g check box is checked To disable the scan feature deselect Keep Scanning The continuous scanning period can be set via the Options and Set Scan Interval menu selections The range for this interval is...

Page 11: ...hat separates the Flags Static data from SBS values changes the height of the Flags Static Data display Selecting View then Auto Arrange returns the splitter bar to its original location The bq20z40 d...

Page 12: ...he bq20z40 using the Write All button The configuration information of the bq29330 and module calibration data is held in the bq20z40 data flash The bq20z40 allows for an automatic data flash export f...

Page 13: ...Calibration If Voltage Calibration is selected enter the number of cells on the pack If Temperature Calibration is selected select the sensor that is to be calibrated If the current source is connecte...

Page 14: ...Screen www ti com Figure 10 Calibration Screen 14 bq20z40EVM 001 SBS 1 1 Impedance Track Technology SLUU320C January 2009 Revised June 2009 Enabled Battery Management Solution EVM Submit Documentatio...

Page 15: ...valid values can cause erroneous results When scaling converted hex values to a higher number of bytes follow these rules When unsigned is selected the left pad contains zeroes When signed is selected...

Page 16: ...by its title and literature number Updated documents can also be obtained through the TI Web site at www ti com Documents Literature Number bq20z40 SBS 1 1 Compliant Gas Gauge With Impedance Track SLU...

Page 17: ...duct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application enginee...

Page 18: ...ce TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonabl...

Page 19: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ20Z40EVM 001...

Reviews: