I2C Registers
21.4.1.8 I2C_WE Register (offset = 34h) [reset = 0h]
I2C_WE is shown in
and described in
Every 1-bit field in the I2C_WE register enables a specific (synchronous) IRQ request source to generate
an asynchronous wakeup (on the appropriate swakeup line). When a bit location is set to 1 by the local
host, a wakeup is signaled to the local host if the corresponding event is captured by the core of the I2C
controller. Value after reset is low (all bits). There is no need for an Access Error WakeUp event, since
this event occurs only when the module is in Active Mode (for Interface/OCP accesses to FIFO) and is
signaled by an interrupt. With the exception of Start Condition WakeUp, which is asynchronously detected
when the Functional clock is turned-off, all the other WakeUp events require the Functional (System) clock
to be enabled.
Figure 21-23. I2C_WE Register
31
30
29
28
27
26
25
24
Reserved
R-0h
23
22
21
20
19
18
17
16
Reserved
R-0h
15
14
13
12
11
10
9
8
Reserved
XDR_WE
RDR_WE
Reserved
ROVR_WE
XUDF_WE
AAS_WE
BF_WE
R-0h
R/W-0h
R/W-0h
R-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
7
6
5
4
3
2
1
0
Reserved
STC_WE
GC_WE
Reserved
DRDY_WE
ARDY_WE
NACK_WE
AL_WE
R-0h
R/W-0h
R/W-0h
R-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 21-16. I2C_WE Register Field Descriptions
Bit
Field
Type
Reset
Description
31-15
Reserved
R
0h
14
XDR_WE
R/W
0h
Transmit draining wakeup enable.
This read/write bit is used to enable or disable wakeup signal
generation when I2C module is in idle mode, the TX FIFO level is
below the threshold and the amount of data left to be transferred is
less than TXTRSH value.
This allows for the module to inform the CPU that it can check the
amount of data to be written to the FIFO.
0x0 = Transmit draining wakeup disabled
0x1 = Transmit draining wakeup enabled
13
RDR_WE
R/W
0h
Receive draining wakeup enable.
This read/write bit is used to enable or disable wakeup signal
generation when I2C is in idle mode, configured as a receiver, and it
has detected a stop condition on the bus but the RX FIFO threshold
is not reached (but the FIFO is not empty).
This allows for the module to inform the CPU that it can check the
amount of data to be transferred from the FIFO.
0x0 = Receive draining wakeup disabled
0x1 = Receive draining wakeup enabled
12
Reserved
R
0h
11
ROVR_WE
R/W
0h
Receive overrun wakeup enable
0x0 = Receive overrun wakeup disabled
0x1 = Receive overrun wakeup enabled
10
XUDF_WE
R/W
0h
Transmit underflow wakeup enable
0x0 = Transmit underflow wakeup disabled
0x1 = Transmit underflow wakeup enabled
3733
SPRUH73H – October 2011 – Revised April 2013
I2C