Ethernet Subsystem Registers
14.5.3.1 CPTS_IDVER Register (offset = 0h) [reset = 4E8A0101h]
CPTS_IDVER is shown in
and described in
.
IDENTIFICATION AND VERSION REGISTER
Figure 14-78. CPTS_IDVER Register
31
30
29
28
27
26
25
24
TX_IDENT
R-4E8Ah
23
22
21
20
19
18
17
16
TX_IDENT
R-4E8Ah
15
14
13
12
11
10
9
8
RTL_VER
MAJOR_VER
R-9D140h
R-4E8A01h
7
6
5
4
3
2
1
0
MINOR_VER
R-4E8A0101h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 14-90. CPTS_IDVER Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
TX_IDENT
R
4E8Ah
TX Identification Value
15-11
RTL_VER
R
9D140h
RTL Version Value
10-8
MAJOR_VER
R
4E8A01h
Major Version Value
7-0
MINOR_VER
R
4E8A0101h
Minor Version Value
1310
Ethernet Subsystem
SPRUH73H – October 2011 – Revised April 2013
Copyright © 2011–2013, Texas Instruments Incorporated