Registers
701
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Enhanced Direct Memory Access (EDMA3) Controller
17.4.3.6.9 Source Active Destination Address B-Reference Register (SADSTBREF)
The source active destination address B-reference register (SADSTBREF) is shown in
and
described in
Figure 17-99. Source Active Destination Address B-Reference Register (SADSTBREF)
31
0
DADDRBREF
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 17-82. Source Active Destination Address B-Reference Register (SADSTBREF)
Field Descriptions
Bit
Field
Value
Description
31-0
DADDRBREF
0
Always reads as 0
17.4.3.6.10 Destination FIFO Set Count Reload Register (DFCNTRLD)
The destination FIFO set count reload register (DFCNTRLD) is shown in
and described in
.
Figure 17-100. Destination FIFO Set Count Reload Register (DFCNTRLD)
31
16
Reserved
R-0
15
0
ACNTRLD
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 17-83. Destination FIFO Set Count Reload Register (DFCNTRLD) Field Descriptions
Bit
Field
Value
Description
31-16
Reserved
0
Reserved
15-0
ACNTRLD
0-FFFFh
A-count reload value. Represents the originally programmed value of ACNT. The reload value is
used to reinitialize ACNT after each array is serviced.