Registers
451
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
15.4.4 Capture 2 Register (CAP2)
The capture 2 register (CAP2) is shown in
and described in
Figure 15-20. Capture 2 Register (CAP2)
31
0
CAP2
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 15-17. Capture 2 Register (CAP2) Field Descriptions
Bit
Field
Value
Description
31-0
CAP2
0-FFFF FFFFh
This register can be loaded (written) by:
• Time-Stamp (i.e., counter value) during a capture event
• Software - may be useful for test purposes
• ACMP active register when used in APWM mode
15.4.5 Capture 3 Register (CAP3)
The capture 3 register (CAP3) is shown in
and described in
Figure 15-21. Capture 3 Register (CAP3)
31
0
CAP3
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 15-18. Capture 3 Register (CAP3) Field Descriptions
Bit
Field
Value
Description
31-0
CAP3
0-FFFF FFFFh
In CMP mode, this is a time-stamp capture register. In APWM mode, this is the period shadow
(APRD) register. You update the PWM period value through this register. In this mode, CAP3
shadows CAP1.