![Texas Instruments AM1808 Technical Reference Manual Download Page 1729](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_10945581729.webp)
Registers
1729
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Universal Serial Bus 2.0 (USB) Controller
34.4.47 Receive Interval Register (Host mode only) (HOST_RXINTERVAL)
The receive interval register (Host mode only) (HOST_RXINTERVAL) is shown in
and
described in
Figure 34-73. Receive Interval Register (Host mode only) (HOST_RXINTERVAL)
7
0
POLINTVL_NAKLIMIT
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 34-77. Receive Interval Register (Host mode only) (HOST_RXINTERVAL) Field Descriptions
Bit
Field
Value
Description
7-0
POLINTVL_NAKLIMIT
0-FFh
For Interrupt and Isochronous transfers, defines the polling interval for the currently-selected
transmit endpoint. For Bulk endpoints, sets the number of frames/microframes after which
the endpoint should timeout on receiving a stream of NAK responses. There is a transmit
interval register for each configured transmit endpoint (except Endpoint 0). In each case, the
value that is set defines a number of frames/microframes (High-Speed transfers), as
follows:
Transfer Type
Speed
Valid values (m)
Interpretation
Interrupt
Low Speed or
Full Speed
1-255
Polling interval is m frames
High Speed
1-16
Polling interval is 2
(-1)
microframes
Isochronous
Full Speed or
High Speed
1-16
Polling interval is 2
(-1)
frames/microframes
Bulk
Full Speed or
High Speed
2-16
NAK Limit is 2
(-1)
frames/microframes
Note: A value of 0 or 1 disables the NAK timeout function.