ADSxx54EVM-PDK Kit Operation
6.4
Device Registers
In addition to the
ADSxx54EVM Settings
page, the GUI also allows access to the SCLK frequency and the
ADSxx54 register settings on the
Device Registers
page of the GUI. Use the EVM software to change the
following register settings of the configuration register (CFR):
•
INPUT_RANGE (CFR.B9)
•
REF_SEL (CFR.B6)
•
STANDBY (CFR.B5)
Use the EVM software to also program the REFDAC register settings. Refer to
of this user
guide, or the ADSxx54 device datasheet for more information.
shows the
Device Registers
page
of the GUI.
Figure 19. Device Registers Page
6.5
Capturing Data with the ADSxx54EVM-PDK
Access the
Data Monitor
page in the GUI to monitor data acquired by the ADSxx54. This GUI page
displays the acquired data versus time. To access the
Data Monitor
page, hover the cursor over the red
arrow at the left center side of the GUI screen; a menu with different GUI pages appear. Click on the
Data
Monitor
option in the menu as shown in
Figure 20. Open the Data Monitor page on the GUI
18
ADS8354EVM-PDK and ADS7854EVM-PDK
SBAU209 – April 2014
Copyright © 2014, Texas Instruments Incorporated