lists the nominal voltages that result from the default configuration.
Table 7-2. Nominal Voltages Resulting From a Default Configuration
Supply Name
Voltage (Referenced to GND)
AVSS
GND (0 V)
AVSS+5V
5 V
DVDD (IOVDD)
3.3 V
AVDD1
5 V
AVDD2
5 V
5.5V
5.5 V
REFP
4.096 V
–2.5V
NA, external supply needed to generate –2.5 V
7.2 EVM Graphical User Interface (GUI) Software Installation
Download the latest version of the EVM GUI installer from the
Tools and Software
folder of the ADS1285EVM-
PDK and run the GUI installer to install the EVM GUI software on your computer.
CAUTION
Manually disable any antivirus software running on the computer before downloading the EVM GUI
installer onto the local hard disk. Depending on the antivirus settings, an error message may appear
or the installer. The .exe file can be deleted.
Accept the license agreements and follow the on-screen instructions shown in
installation.
Figure 7-2. ADS1285 Software Installation Prompt
ADS1285EVM-PDK Initial Setup
14
ADS1285EVM-PDK Evaluation Module
SBAU394A – APRIL 2022 – REVISED SEPTEMBER 2022
Copyright © 2022 Texas Instruments Incorporated