Shorted jumper (J13B)
USB connector
+
±
Open jumper (J12)
5V
Power Input
ADS126xEVM Hardware
2.3.1.2
Bench Power Supply
To use the MMB0 with an external bench power supply, remove the J12 jumper and leave it open, as
shown in
. Removing the jumper allows an external 5-V power supply to be connected to +5VA on
the J14 terminal block. Jumper J13B co5VA to +5VD and must remain shorted. In this
configuration, the MMB0 derives the 3.3-V digital supply for the ADS126xEVM from the 5-V bench supply,
and the bench supply directly supplies the analog supply voltage for the ADS126xEVM.
Figure 7. MMB0 Configuration for a Unipolar Bench Power Supply
9