Quick-Start Procedure for Bypass LMFS8224 Mode in ADC32RF44 and Internal Clocking
31
SLAU620D – April 2016 – Revised August 2017
Copyright © 2016–2017, Texas Instruments Incorporated
ADC32RFxx-EVM
6.3
High Speed Data Converter Pro (HSDC Pro)
1. Open High Speed Data Converter Pro (v4.5 or newer) by going to
Start Menu
→
All Programs
→
Texas Instruments
→
High Speed Data Converter Pro
.
2. Click
OK
to connect to the TSW14J56. If there is more than one TSW14J56 connected to the host PC,
select the appropriate serial number of the board to be programmed.
3. Select the
ADC
tab at the top of the GUI.
4. Use the
Select ADC
drop-down menu at the top left corner to select
ADC32RF45_LMF_8224
.
Figure 29. HSDC Pro Device Selection LMFS_8224 Mode
5. When prompted to update the firmware for the ADC, click
Yes
and wait for the firmware to download to
the TSW14J56.
6. After the firmware download has completed, enter “2949.12M” into the
ADC Output Data Rate
field at
the bottom left corner of the HSDC Pro GUI.
7. Select “Channel 1/2” in the channel select window located at the top middle of the GUI.
8. Click the
Instrument Options
menu at the top of HSDC Pro and select
Reset Board
.
9. Click
Capture
in HSDC Pro to capture data from the ADC.
10. The result should match the example capture in
Figure 30. Example Capture from Channel A – LMFS8224 Mode