Teufel T 400 Technical Description And Operating Instructions Download Page 6

6

 

 • T 400

Connecting

Connection variations

In addition to a standard connection, where every speak-
er column is connected to the amplifi er with a cable, you 
can also choose the variants “Bi-Wiring” or “Bi-Amping”.

Standard connection

With this connection, the T 400 speakers are connected 
like conventional speakers with one 2-core speaker cable 
each. The contact bridges between the connector termi-
nals may not be removed in the process; you can connect 
the cables accordingly to the top or bottom terminals.

Bi-Wiring

For this, the high and midrange speakers are connected 
with one cable and the two low range speakers are con-
nected with a second cable. This allows you to reduce 
distortion with very long cables.

Bi-Amping

For this, the high/midrange and low range speakers have 
their own amplifi ers.

Connecting the cables

Danger

Danger of injury/damage!

Arrange the cables so that they do not pose a 
trip hazard.

Turn off your amplifi er.

1. 

Lay the speaker cable from your amplifi er to each 

2. 

of the speakers. This cable should be a high-quality 
double-core speaker cable with marked wires. The 
cross-section should amount to at least 2.5 mm

2

.

A connector terminal with four 

3. 

binding posts is located on the 
back of each speaker. You can 
connect the speaker cables using 
banana plugs or directly. We 
only describe the direct connec-
tion here. The terminals are each 
marked red (+) and black (-).

Make sure the polarity is correct!

Connect the like coloured terminals of your 
speakers and amplifi er with one another. 

Otherwise the sound quality will suffer. The individual 
strips of the speaker cables are marked with different 
colours or forms to facilitate this.

You only have to remove the 

4. 

contact bridges when using 
 Bi-Wiring or Bi-Amping: Turn 
the binding posts counterclock-
wise until loose and then pull 
out the contact bridges. The 
top terminals lead to the high 
range and midrange speakers, 
the bottom terminals lead to the 
low range speakers.

Split the core on 

5. 

both ends up to 
approximately 
30 mm and 
remove approxi-
mately 10 mm 
of the insulation 
on each piece. 
Twist the core so 
that no wires are protruding.

Turn the binding post counter-

6. 

clockwise until loose. Run the 
stripped cable into the hole 
that is now visible. Turn the 
post clockwise until closed. The 
cable has now been clamped 
in place.

Connect the other end of the 

7. 

speaker cables to your ampli-
fi er. The operating instructions 
of the appliance should contain 
notes on this.

91556 GB 20100902.indd   6

91556 GB 20100902.indd   6

02.09.2010   15:20:45 Uhr

02.09.2010   15:20:45 Uhr

Summary of Contents for T 400

Page 1: ...Technical description and operating instructions Stereo Floor Speakers with Bi Wiring Bi Amping T 400...

Page 2: ...conditions 3 Returns 3 Proper use 3 Safety notes 4 Caution icons 4 Safety notes 4 Unpacking and setup 5 Check to be sure 5 Location tips 5 Removing the protective grids 5 Connecting 6 Connection vari...

Page 3: ...y merchant In the case of a private re sale of Teufel products the warranty may be transferred to the purchaser as long as the original proof of purchase is also passed on to the purchaser Returns Teu...

Page 4: ...t volume control to a low setting When the volume is set high always keep a certain distance from the unit and never place your ear directly on the speaker To avoid damage to health avoid extended lis...

Page 5: ...e distance in front of the speakers see the adjacent graphic and there are no objects between the listener and speakers tables or the like Unfortunately available space furnishing or other circumstanc...

Page 6: ...to at least 2 5 mm2 A connector terminal with four 3 binding posts is located on the back of each speaker You can connect the speaker cables using banana plugs or directly We only describe the direct...

Page 7: ...lean ing Technical data This product conforms with Council of the European Union guidelines 2004 108 EC and 2006 95 EC Technical changes reserved Disposing of the unit Used units must not be disposed...

Page 8: ...service department Lautsprecher Teufel GmbH Gewerbehof Buelowbogen Aufgang D1 10783 Berlin Germany Buelowstr 66 Tel 00800 200 300 40 Fax 49 0 30 300 930 930 www teufelaudio com No liability is accepte...

Reviews: