PREDISPOSITION FOR THE INSTALLATION

Minipool

The minipool is designed specifically for built-in type 

installation, with the edge exactly at floor level; refer to the 

dimensions indicated in the drawings when preparing the pit.

(N.B given that dimensional specifications may be 

subject to slight variations, check all measurements 

before proceeding with installation).

The pit for the built-in minipool should be cast in concrete, 

observing the dimensions indicated in the drawing and 

making certain that the structure is perfectly level. The plinth 

or slab directly supporting the minipool must be able to 

support the load (see table on page 2).

Leave a void (A) at least 40 cm wide all round the minipool 

to ensure sufficient freedom of access to the plumbing and 

electrical equipment installed beneath the tub.

The void must be covered with removable grate decking 

carried on suitably sturdy supports and affording air passages 

so that the pit will be adequately ventilated.

Provide channels and a drain outlet (S) at the bottom of the pit 

so that water will not collect and stagnate.

PREDISPOSITIÓN CONNECTS HYDRÁULIC

The contractor will supply all the plumbing material (including 

fittings, ball valves, etc.), needed to connect the minipool 

to the Spa-pack and to the overflow tank, and must install 

suitably proportioned gullies, inspectable and accessible for 

cleaning purposes, into which the line X will be connected.

In particularly cold climates, where there is a risk of 

residual water freezing in pipelines, it is advisable to 

install drain valves at strategic points on the various 

circuits, so that the system can be emptied completely.

IMPORTANT: before making any permanent connection to 

the main drain, contact the local authorities to check on 

regulations governing the disposal of chemically treated 

water.

FILLING: 

the recommended method of filling the Teuco is to 

use an ordinary hose, taking care not to immerse the end as 

this could allow reflux of water back into the main (3).

IMPORTANT: Once installation is complete, if Teuco Spa-

Pack was not used, please make sure that the maximum 

suction power of the intake openings is in line with 

the limits set by the standard IEC 60335-2-60: "Safety - 

Particular requirements for whirlpool baths and whirlpool 

spas".

IMPORTANT: if the intention is to connect the minipool 

permanently to the water supply, suitable non-return 

devices must be incorporated to prevent reflux back to 

the water main.

Contact the local authorities before proceeding with this 

type of installation.

Ø

Z

80 mm

X

2"/63mm

I

2"/63mm

A

2"/63mm

W

2"/63mm

PREDISPOSITION OF CONNECTIONS

Z

 - Drain channel

X

 - Recirculation and drain input

I

 - Hidro suction

A

 - Air Entry (To Injectors) 

W

 - Water Entry (In To Jet Ring) 