Troubleshoot

Problem

Cause

Corrective 

No light

•  No power.

• 

Wrong connection or unsecure connec

-

tion.

•  Check the power.

• 

Check the connection.

Wrong Colour

• 

Wrong connection of tunable white 

wires.

•  Re trace and reconnect 

tunable white wires.

Uneven intensity be-

tween front and rear of 

the strip, with voltage 

drop

•  Output cable is too long.

•  Cable diameter is too small.

•  Overload beyond driver capability.

•  Overload beyond receiver capability.

•  Reduce cable or loop sup-

ply.

•  Change to a thicker cable.

•  Replace with a suitable 

higher power driver.

•  Add a power repeater.

No response

from the remote

• 

The battery has no power.

•  Beyond controllable distance.

•  The controller isn’t synchronised with the 

remote.

• 

Replace battery.

•  Reduce remote to receiver 

distance.

•  Re-sync the remote.

3) Repeat the process to allocate zones for all receivers.