Synchronising the remote to receiver
Brighter for longer
CONTROLLER AND RECEIVER
www.teucerled.co.uk
1)
Ensure the receiver has power. Press the match button on the receiver. Indicator will begin flashing.
4) To restore to factory default settings and delete the allocated con
-
troller, press and hold the match button longer than 5 seconds.
2)
Choose the required zone on the remote to allocate the receiver within 5 seconds after pressing the
match button. The indicator will stop flashing, and the controller will be synchronised.
Match bu�on
Indicator
R3C
Press the zone
you wish to allocate
Troubleshoot
Problem
Cause
Corrective
No light
• No power.
•
Wrong connection or unsecure connec
-
tion.
• Check the power.
•
Check the connection.
Wrong Colour
•
Wrong connection of tunable white
wires.
• Re trace and reconnect
tunable white wires.
Uneven intensity be-
tween front and rear of
the strip, with voltage
drop
• Output cable is too long.
• Cable diameter is too small.
• Overload beyond driver capability.
• Overload beyond receiver capability.
• Reduce cable or loop sup-
ply.
• Change to a thicker cable.
• Replace with a suitable
higher power driver.
• Add a power repeater.
No response
from the remote
•
The battery has no power.
• Beyond controllable distance.
• The controller isn’t synchronised with the
remote.
•
Replace battery.
• Reduce remote to receiver
distance.
• Re-sync the remote.
3) Repeat the process to allocate zones for all receivers.
LR-4TWN and R3C
4 zones RF controller and receiver for tunable white LED strip