Summary of Contents for DN-109NP

Page 1: ...1490K03I TETRALEC E I S L Certified company OPERATION MANUAL FOR DISPLAYS SERIES DN 109NP DN 119NP DN 129NP AND DN 189NP ...

Page 2: ......

Page 3: ... consumption 2 4 2 3 Dimensions and mounting of the displays 2 5 2 3 1 Dimensions and mounting of the DN 109 and DN 119 2 5 2 3 2 Dimensions and mounting of the DN 129 and DN 189 2 6 3 INSTALLATION 3 1 3 1 Power supply 3 1 3 2 Connecting to the Profibus line 3 2 4 OPERATION 4 1 4 1 Initial reset 4 1 4 2 LEDs Profibus module 4 1 4 3 Programming parameters 4 2 4 3 1 Enter to modify parameters 4 2 4 ...

Page 4: ...4 6 2 Parameters to define the internal bit r2 4 8 4 6 3 Parameters to define the colour 4 9 4 6 4 Work with only one colour 4 9 ...

Page 5: ...istics is the large size of the characters DN 109NP of 57mm legible at 30m DN 119NP of 100 mm legible at 50m DN 129NP of 250 mm legible at 120m DN 189NP of 180 mm legible at 90m As with other display series the DN 109NP DN 119NP DN 129 and DN 189NP series is also available in one or two sided versions which provides multiple solutions and installation possibilities It is surface mounted with fixtu...

Page 6: ......

Page 7: ...l Conditions Operation Temperature 20 to 60ºC Storage temperature 30ºC to 70ºC Humidity 5 95 RH non condensing Maximum environmental illumination 1000 lux Sealing IP41 or IP65 2 1 2 Electrical characteristics of the DN 119 displays Supply Voltage 88 to 264 VAC 47 to 63Hz or 19 to 36VDC Consumption See Display weight and power consumption Display 7 segments 100mm high decimal point Red Led colour V...

Page 8: ...ature 20 to 60ºC Storage temperature 30ºC to 70ºC Humidity 5 95 RH non condensing Maximum environmental illumination 1000 lux Sealing IP41 or IP65 2 1 4 Electrical characteristics of the DN 129 displays Supply Voltage 88 to 264 VAC 47 to 63Hz or 19 to 36VDC Consumption See Display weight and power consumption Display 7 segments 250mm high decimal point Red Led colour Viewing distance max 120 meter...

Page 9: ...09 9D TL 5 5 34 6 DN 109 9D TV 5 5 30 5 DN 109 10S 4 5 17 2 DN 109 10S TL 5 0 19 2 DN 109 10S TV 5 0 17 2 DN 109 10D 5 5 33 7 DN 109 10D TL 6 0 37 7 DN 109 10D TV 6 0 33 7 2 2 2 DN 119 weight and power consumption Reference Display Weight kg Power W Reference Display weight kg Power W Reference Display weight kg Power W DN 119 3S 4 0 10 8 DN 119 3S TL 4 5 13 4 DN 119 3S TV 4 5 10 8 DN 119 3D 4 0 1...

Page 10: ...9 9S 11 0 56 6 DN 189 9S TV 13 0 56 6 DN 189 9D 13 5 113 2 DN 189 9D TV 15 5 113 2 DN 189 10S 12 0 62 9 DN 189 10S TV 14 0 62 9 DN 189 10D 15 0 125 8 DN 189 10D TV 16 5 125 8 2 2 4 DN 129 weight and power consumption Reference Display Weight kg Power W Reference Display weight kg Power W DN 129 2S 6 5 13 DN 129 2S TV 9 5 13 DN 129 2D 8 0 26 DN 129 2D TV 11 5 26 DN 129 3S 8 5 20 DN 129 3S TV 11 5 2...

Page 11: ... 122 DN 109 6S 336 122 DN 109 6S T 430 122 DN 109 7S 382 122 DN 109 7S T 478 122 DN 109 8S 430 122 DN 109 8S T 526 122 DN 109 9S 478 122 DN 109 9S T 574 122 DN 109 10S 526 122 DN 109 10S T 622 122 DN 119 3S 324 177 DN 119 3S T 504 177 DN 119 4S 414 177 DN 119 4S T 594 177 DN 119 5S 504 177 DN 119 5S T 684 177 DN 119 6S 594 177 DN 119 6S T 774 177 DN 119 7S 684 177 DN 119 7S T 864 177 DN 119 8S 774...

Page 12: ...189 7S TV 1460 251 67 DN 189 8S 1300 251 67 DN 189 8S TV 1620 251 67 DN 189 9S 1460 251 67 DN 189 9S TV 1780 251 67 DN 189 10S 1620 251 67 DN 189 10S TV 1940 251 67 DN 129 2S 515 366 186 DN 129 2S TV 985 366 186 DN 129 3S 750 366 186 DN 129 3S TV 1220 366 186 DN 129 4S 985 366 186 DN 129 4S TV 1455 366 186 DN 129 5S 1220 366 186 DN 129 5S TV 1690 366 186 DN 129 6S 1455 366 186 DN 129 6S TV 1925 36...

Page 13: ...9NP and DN 189NP should not be installed in places with an illumination level in excess of 1000 lux Neither should the display be placed in direct sunlight as visibility would be lost In the electrical installation proximity to lines of high intensity circulation and high voltage lines must be avoided as well as proximity to High Frequency generators and U F converters for motors 3 1 Power supply ...

Page 14: ...l resistances will be enabled on the ends of the network to adjust network impedance The Profibus connectors include a switch to enable resistances Power lines that may generate electrical interference will be avoided where possible on the network layout CONNECTOR PROFIBUS OP Operation ST Status Pin 1 NC Pin 6 5V Bus Output Pin 2 NC Pin 7 NC Pin 3 Line B Pin 8 Line A Pin 4 RTS Pin 9 NC Pin 5 GND B...

Page 15: ...lay is connected to the network the OP led will light up green From this point any one of the following three situations may occur a The display receives data from the Ethernet network and displays it b The display does not receive data and the time without data equals zero Continues to show the decimal points c The display does not receive data and the time without data is not equal to zero After...

Page 16: ...rameter is indicated by the digit on the left and the decimal point flashes while the digit on the right is off 4 3 1 Enter to modify parameters In order to enter the sequence to modify the parameters the Advance key must be pressed and held for three seconds After this the first parameters will be displayed showing the most significant digit flashing There are then two options 1 Modify the parame...

Page 17: ...ceiving data or that the data is incorrect The warning occurs if the programmed time is exceeded Each time that a communication is received correctly the time is reset to zero The code 00 No time does not trigger any warning To indicate that the time limit has been exceeded a dash will be displayed on each digit Code Time Code Time 00 Without time 11 1 min 01 2 s 12 2 min 02 4 s 13 5 min 03 6 s 14...

Page 18: ... When Profibus network is working properly the value sent through the net is displayed 4 3 3 6 Parameter 6 Colour option displays See 4 6 Colour configuration 4 3 3 7 Parameter 7 Colour option displays See 4 6 Colour configuration 4 3 3 8 Parameter 8 Colour option displays See 4 6 Colour configuration 4 3 3 9 Parameter 9 Colour option displays See 4 6 Colour configuration 4 3 3 10 Parameter nr r1 ...

Page 19: ...or 110001d 110101d 4 4 1 Block structure 4 double words DW are sent in each transmission block Total 16 bytes The information that the block must contain is different depending on the type of frame programmed in parameter 2 The transmission sequence is started with DW1 byte A and ends with DW4 byte P DW1 DW2 DW3 DW4 A B C D E F G H I J K L M N O P 4 4 2 Data type 0 Display a double integer DW The ...

Page 20: ...le for a 6 digits display 2 decimals DW1 DW2 DW3 DW4 Display 43h 9Ah C1h 3Dh 00 00 00 00 00 00 00 00 00 00 00 00 5 6 7 8 9 DW1 DW2 DW3 DW4 Display 42h F6h 14h 7Bh 00 00 00 00 00 00 00 00 00 00 00 00 7 8 9 1 2 3 4 4 5 1 Valid characters Numerical displays can only display numbers and some characters Character 0 1 2 3 4 5 6 7 8 9 A b HEXA 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 41h 42h DEC 48d 49d 5...

Page 21: ...2 DW3 DW4 xx xx xx xx xx xx xx xx xx xx xx xx xx xx X c xx Any value C Colour X Character X 4 5 GSD module installation The appropriate GSD module must be installed to communicate with a display This can be obtained from the website www lartet com Hardware configuration must be selected to install the GSD module Select Tools from the menu then Install new GSD file and follow the instructions To in...

Page 22: ...ay or hysteresis Parameter 7 is used to set up the trigger level The most significant digit allow setting up a negative value Parameter 6 Left Digit Control bit Right Digit Set Reset 0 ON if Value Parameter 7 0 No delay No hysteresis 1 ON if Value Parameter C 1 Delay 1s 2 Always OFF 2 Delay 2s 3 Delay 4s 4 Delay 6s 5 Delay 10s 6 Hysteresis 2 7 Hysteresis 4 8 Hysteresis 8 9 Hysteresis 12 4 6 2 Para...

Page 23: ...pon pressing the next parameter is shown Colour if internal bit r2 is ON To change the colour push key Upon pressing the next parameter is shown Colour if internal bits r1 and r2 are ON To change the colour push key Upon pressing the next parameter is shown 4 6 4 Work with only one colour To work always with only one colour set up the following parameters Parameter Value 6 20 7 0 8 20 9 0 nr colou...

Page 24: ......

Page 25: ...rch 2013 Updated introduction in 4 4 Revision H September 2013 Updated dimensions and weight of DN 109 3 Paragraphs 2 2 1 and 2 3 1 Revision I October 2013 Updated electrical characteristics of the 24VDC power Paragraphs 2 1 and 3 1 ...

Page 26: ...e aforementioned product complies with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagnetic Compatibility Standard UNE EN 61000 6 4 Generic Emission Standard Industrial environment Standard UNE EN 61000 6 2 Generic Immunity Standard Industrial environment Directive 2011 65 CE...