Dear customer,
Congratulations on choosing
your highly reliable, easy to
maintain Tetra Water Pump.
This TÜV tested product is
manufactured from the highest
quality materials. As a result, you
can be sure of its reliability and
safety. Please read the following
instructions very carefully before
using your new Tetra WP.
Tetra WP Water Pump
A.
Pump Body
B.
Impeller
C.
Pump Housing
D.
Control Regulator
E.
Suction Cups
(2x for WP 300,
4x for WP 600 / WP 1000)
F.
Bearing (Spare Part only)
for WP 600 / WP 1000
Instructions
Installation
Attach the enclosed suction
cups into the openings located
on the bottom of the pump body
and pump housing.
(fig. 1)
Using the suction cups, attach
the water pump below the
water surface at your chosen
position on the bottom or the
side of the tank.
(fig. 2)
Operation
To adjust the water flow, slide
the flow rate adjuster within
the minimum and maximum
range.
(fig. 3)
Ensure that the electrical cord
loops (indoor applications)
below the electrical outlet
forming a „drip loop“. This
prevents the water from
running down the cord and
into the electrical outlet. (
fig. 5)
To start the water pump,
simply plug it in!
Operation/ Maintenance
Attention! Before any kind
of maintenance is carried out,
ALWAYS disconnect the
electrical supply of the pump
and any other appliance
placed in the water.
•
Regular
cleaning
and
maintenance is recommended
for maximum use and
performance
• Remove the pump housing
from the motor body
(fig. 4)
• Remove the impeller from
the mounting
•
Wash the pump wheel
and clean with a soft brush
• Reassemble everything in
reverse order
Safety Regulations
Attention! Before any kind
of maintenance is carried
out,
always disconnect the
electrical supply of the pump
and any other appliance
placed in the water.
The pump will be destroyed
if operated dry. Always
ensure that there is water
water flowing through the
pump when in operation.
The pump is intended
for indoor use only in
temperatures that do not
exceed 35°C.
Before connecting to the
main power supply be sure
the cord and the pump are
undamaged. The cord of this
pump cannot be replaced
or repaired: in case of
damage, the entire device
must no longer be used.
This appliance is not
intended for use by persons
(including children) with
reduced physical, sensory
or mental capabilities,
or lack of experience
and knowledge, unless
they have been given
supervision or instruction
concerning use of the
appliance by a person
responsible
for
their
safety. Children should be
supervised to ensure that
they do not play with the
appliance.
Guarantee
Tetra guarantees that your
Tetra WP will be repaired
or replaced free of charge
within two years from the
date of purchase if it fails
to work because of faulty
material or workmanship.
This guarantee does not
cover normal wear and
tear, nor any deterioration
suffered through overloading,
improper use, negligence
or accident. Similarly any
modifications made by the
purchaser to the appliance
will cause the guarantee to
be null and void. Please keep
proof of purchase.
Tetra GmbH
D-49304 Melle, Germany
www.tetra.net
Technical Data
Model
Flow rate
l/h
Aquarium
size
in litres
H. max
Watt
WP 300
WP 600
WP 1000
300
600
1000
Max 100 l
Max 200 l
Max 300 l
0.5 m
1.30 m
2.0 m
5
11
25
230V 50 Hz
6
7