Key

Description

IQ 10

IQ 20

IQ 30

IQ 45

IQ 60 

A

Motor Assembly

AQ-78149

AQ-78152

AQ-78157

AQ-78158

AQ-78154

B

Tube Assembly

AQ-78150

AQ-78153

AQ-78153

AQ-78153

AQ-78155

C

Dampeners

AQ-78151

AQ-78151

AQ-78151

AQ-78151

AQ-78151

D

Impeller Assembly AQ-78159

AQ-78160

AQ-78161

AQ-78162

AQ-78163

E

Bio-Grid

AQ-78164

AQ-78165

AQ-78166

AQ-78166

AQ-78166

REPLACEMENT PARTS LIST

A

C

B

E

D

AQ-78151

AQ-78164

AQ-78165

AQ-78166

AQ-78159

AQ-78160

AQ-78161

AQ-78162

AQ-78163

x2

*Impeller sold separately

1.  Filter Lid
2.  StayClean Cartridge
3.  Bio-Grid
4.  Transfer Tube
5.  Flow Control
6.  Filter Body
7.  Transfer Tube Dampener
8.  Motor Dampener
9.  Dampener Attachment Plate

10.  Motor Cover
11.  Standoff (removable)
12.  Motor Housing
13.  Volute
14.  Impeller
15.  Intake Tube
16.  Extension Tube
17.  Strainer

1

2

3

4

5

6

7

8

9

10

11

12

14

13

15

16

17

PARTS DIAGRAM

FLOW RATE

To select maximum flow, pull the flow control dial toward the front of 
the filter (

toward the "+" symbol

). To lessen flow, push the flow control dial 

toward the back of the filter (

toward the "-" symbol

). You will know if your 

filter is running at a reduced flow rate because the dial will turn red.

IQ Filter lowest flow rates (flow control knob set to lowest setting)

• IQ10: 10 GPH
• IQ20: 10 GPH
• IQ30: 10 GPH
• IQ45: 20 GPH
• IQ60: 110 GPH

Maximum flow

Minimum flow

1.  Unplug filter and lift out of the water
2.   Remove Strainer and Extension Tube by pulling 

down from Impeller Cover as shown (fig. 1)

3.   Remove Impeller Cover with a screwdriver using the slot provided (fig. 2)
4.  Remove the rubber impeller endcap by pulling off impeller shaft (fig. 3)
5.   Pull Impeller Assembly out and away from shaft (note: the magnet on 

the impeller may require some force to remove it from the shaft) (fig. 4)

6.  Examine all parts for debris that could cause blockage
7.   Remove debris from Strainer, Extension Tubes, and 

Impeller Cover by rinsing under cool water

8.   Remove any material that may have twisted around 

the Impeller Shaft with a needle or tweezers

9.  Rinse and clean Impeller Assembly by rinsing under cool water

10.  Reassemble system and place on aquarium (fig. 5)

fig. 2

fig. 3

fig. 4

fig. 5

fig. 1

WHISPER IQ IMPELLER REMOVAL

To access impeller for cleaning and replacement:

NOTE: DO NOT OPERATE FILTER WITHOUT IMPELLER