7
Safety First
Never submerge the unit in water.
Always switch off the unit if there is
no water running through it to pre-
vent overheating. This unit pro-
duces harmful ultra violet light. Do
not look directly at the unshielded
bulb as damage to the eyes may
occur.
Monitoring of lamp operation
should only take place by looking
through the transparent hose con-
nectors.
When connecting the unit to the
mains it is recommended that an
inline residual current device
should be installed or that the unit
be wired directly into the mains
using a residual circuit breaker.
Guarantee
Tetra guarantees that your Tetra
tec
®
UV 400 will be repaired or replaced free
of charge for two years from the date of
purchase if it fails to work because of
faulty materials or workmanship. This
guarantee does not cover normal
wear and tear, nor any deterioration
suffered through overloading,
improper use, negligence or accident.
Similarly any modifications made by
the purchaser to the appliance will
cause the guarantee to null and void.
Please keep your receipt as proof of
purchase and return the enclosed
guarantee card within 14 days of pur-
chase to validate your guarantee.
Technical Data
Compatible with the following Powerhead / Water Pump / Canister Filter size.
Aquarium size
Maximum pump flow rate
(litres per hour)
60 - 200
120 - 400
200 - 400
400 - 1000
sealing ring is in place before screw-
ing the hose connector into the unit.
Note: the unit should always be
placed after the filter. That way, the
water flowing through the UV will be
free of particles that may clog the unit
and reduce the efficiency of
the UV
light penetration.
3.
The inlet and oulet hoses can be
fitted to the unit and should be
secured using hose clips (not includ-
ed)
4.
Plug the unit into the electrical
outlet to start the UV operation. When
working a purple (ultra violet light)
can be seen through the transparent
hose connectors. The harmful UV
light will not pass through the trans-
parent connectors.
The unit should remain in operation
24 hours a day for best results.
NB: Switch off the UV unit when
using fish treatments or medications.
5.
An operational test can only be
carried out when the equipment is
fully assembled.
Maintenance and Care
When carrying out any maintenance
the unit must be disconnected from
the mains. Always remove inlet and
outlet hoses and drain the unit of
water before cleaning. Carefully dis-
mantle the unit by first unscrewing
the unit cap and removing the bulb.
The quartz tube may be loosened by
using a small coin or a screwdriver
and can then be carefully removed.
Clean with a soft cloth to avoid
scratching the quartz. When
reassembling ensure that the sealing
rings are properly seated (lubricate
with a small amount of petroleum
jelly if necessary)
The UV-C bulb should be replaced
after 8000 hours (about once per
year) in order to guarantee efficient
operation.
Replacement bulbs and quartz tubes
are available from your local
Tetra
tec
®
retailer.
Tetra GmbH
D-49304 Melle,
Germany
www.tetra.net