3. Call an electrician when in doubt. Pump should be connected to a separate 15 amps circuit breaker

or 15 amp fuse block. Note that, plugging into existing outlets may cause low voltage at motor,

causing blown fuses,  tripping of Thermal  Overload,  or potentially burning out the pump.

4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory.

Teton XPF pumps come with a grounding conductor and a grounding-type attachment plug.

Do not connect pump to a power supply until permanently grounded. For maximum safety, connect

pump to a circuit equipped with a Ground Fault Circuit Interrupter (GFCI) device when you position

the pump's grounding wire.

5. Voltage of power supply must match the voltage of the pump.

6. Before installing pump, clear skimmer or pond of debris or sediment.

! WARNING

Teton XPF pumps are not designed for and CANNOT be installed in locations

classified as hazardous.

7. 

! WARNING 

The following may cause severe damage to pump and may void warranty:

(a) Using an extension cord.

(b) Cutting off the ground pin or using an adapter fitting.

(c) Working on pump or switch while plugged in.

(d) Removing motor housing, unscrewing impeller, or otherwise removing impeller seal.

(e) Pumping chemicals or corrosive liquids.

(f) Pumping gasoline or other flammable liquids.

8. Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe may all be used. All piping

must be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded

joints unless specified otherwise. Be sure to seal the thread connection with tape seal when using

the pipe fitting to connect to the flange.

Electrical Wiring 

Electrical Wire Connection: 

! WARN I NG

Verify that the voltage and frequency of the pump shown on the nameplate corresponds to those

available on the main. The installer must make sure that the electric system is grounded in accordance with current

building code.

All plugs and connections should be located remotely from the pond, protected from water. Before us­

ing the pump, always inspect it visually (especially power cable and plug). 

Do not use the pump if it is damaged. If the pump is damaged, have it inspected by a professional or 

the Authorized Dealer where it was purchased. Make sure that electric connections are protected from 

flooding, heat, oil or sharp objects.

! WARNING

The power cable must be replaced by 

qualified profes­

sional only. 

Grounding: The plug of the power cable has a double grounding contact, so that grounding will take 

place by simply inserting the plug. 

Overload protection: 

The XPF series pumps have been designed with a built in Thermal Overload switch. The pump will 

immediately stop if the Thermal Overload switch activates. The motor restarts automatically after it 

has cooled down. 

-5-

Summary of Contents for XPF3700

Page 1: ...ility Pump Warranty Instruction Manual TETON P O Box 1044 XPF3700 XPF4500 XPF5200 XPF6000 SAN LEANDRO CA 94577 0118 3900 GPH 1 5HP 4700 GPH 1 3HP 5400 GPH 1 2HP 6200 GPH 1HP www tetonus com 800 752 03...

Page 2: ...ref erence in case questions arise If this instruction manual should become lost or damaged ask your nearest dealer or Teton Dynamics for another copy Contents Prior to Operation 2 Specification 3 In...

Page 3: ...Ft GPH inch mm 115V 60Hz XPF3700 1 5 380 1 5 38 11 5 2026GPH 22 5 3900GPH 9 4 X 6 5 X 14 240x165x355mm 9 4 X 6 5 X 14 XPF4500 1 3 470 2 50 13 3480GPH 27 5 4700GPH 240x165x355mm XPF5200 1 2 620 2 50 1...

Page 4: ...Do not use this pump for other than its intended use The use of attachments not recommended or sold by the pump manufacturer may cause an unsafe condition Do not install or store the pump where it wil...

Page 5: ...mable liquids 8 Piping Plastic PVC pipe drain hose galvanized steel or copper pipe may all be used All piping must be clean and free of all foreign matter to prevent clogging Use thread compound on al...

Page 6: ...negligence c to normal maintenance services and the parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade pr...

Page 7: ...is too high or the pipe size is too small Reduce vertical dis tance or increase the pipe size fittings Pump is air locked Start and stop several times by plugging and unplugging cord Check for clogge...

Page 8: ......

Reviews: