![TESY HPWH 2.1 200 U02 Service Manual Download Page 4](http://html1.mh-extra.com/html/tesy/hpwh-2-1-200-u02/hpwh-2-1-200-u02_service-manual_1092664004.webp)
Page
4
of
35
B. DESIGN OVERVIEW
1
Heat pump.
2
Control panel.
3
External PVC jacket.
4
Enameled storage tank
5
Upper storage tank probe.
“T3”
6
Lower storage tank probe. “
T2”
7
Refrigerant recharge needles.
8
Ambient air recirculation fan.
9
Electronically regulated expansion valve valve.
10
High-efficiency finned evaporator.
11
Air inlet (
∅
160 mm).
12
Air outlet (
∅
160 mm).
13
Hermetically-sealed rotary compressor.
14
Compressor’s accumulator
15
(1.5 kW
– 230 W) El. heating element
16
Condenser outlet line - liquid
17
Condenser inlet line
– hot gas
18
Replaceable magnesium anode.
19
Hot water outlet connection (G 1”).
20
Recirculation fitting (G ¾”).
21
Evaporator’s distributor
22
Condensates drain (G 3/4”).
23
Solar coil (G 1”; 1.2 m
2
surface).
24
Cold water inlet connection (
G1”).
25
50 mm polyurethane insulation.
26
High pressure switch
– automatic reset.
27
Safety thermostat, manual reset.
28
Controller box.
29
Probe for solar coil thermosensor.
30
Low pressure switch
– automatic reset.
31
4-way defrosting valve
32
Upper decorative panel
33
Back decorative panel
34
Front decorative panel
35
Lower decorative panel (condense trap)
36
Condenser.
37
Protective fan grid
38
Return gas temperature
“T5”
39
Coil temperature
“T4”
40
Bolts M6x60
41
Ambient temperature