TeSuCo Oxyturbo Nitrogen 6000 Operating Instructions Manual Download Page 2

2

 CAUTION

1. FUNCTION

TECHNICAL DATA

Read the following instructions carefully before using the 
pressure regulator, and keep them for future reference. 
The instructions provide all the information necessary 
for correct use of the instrument, to avoid damage and 
danger. Tesuco

®

/OxyTurbo is not responsible for any 

damage occurring due to incorrect use of the instrument, 
or to modifications made to it.

  

The function of the pressure regulator is to reduce and stabilize the pressure of a gas; the 
regulator changes the pressure at which the gas is kept in the cylinder into the pressure 
needed to use for the application.

  

The pressure regulator has been designed so as to be used only and exclusively with the 
type of gas and at the pressures which are shown by the marking.

  

To try and use the pressure regulator with types of gases and pressures other than those 
indicated can be dangerous.

1.

  Cylinder valve

2.

  Inlet connection "O" ring (seal)

3.

  Inlet connection (nut & stem)

4.

  High pressure gauge

5.

  Low pressure gauge

6.

  Pressure adjusting knob

7.

  Outlet connection

8.

  Adaptor 1/4 - 5/16

9. 

Relief valve

10.

 Bonnet

11.

 Body

12.

 Gauge protectors

13.

 Markings

PARTS LIST  

(See page 7)

P1 = Inlet Pressure     P2 = Outlet Pressure     Q1= Maximum Delivery Flow Rate

Gas

N2

Colour

Blue

ID

N

P1 kPa

30,000

K-Class

-

P2 kPa

6,000

Q1 m³/h

50

Nitrogen 6000

Summary of Contents for Oxyturbo Nitrogen 6000

Page 1: ...1 Operating Instructions Nitrogen 6000 Regulator HVAC R High Flow www tesuco com au QUALITY GAS EQUIPMENT ...

Page 2: ... cylinder into the pressure needed to use for the application The pressure regulator has been designed so as to be used only and exclusively with the type of gas and at the pressures which are shown by the marking To try and use the pressure regulator with types of gases and pressures other than those indicated can be dangerous 1 Cylinder valve 2 Inlet connection O ring seal 3 Inlet connection nut...

Page 3: ...ront of the cylinder valve 1 Position the pressure regulator with the gauges the right way up Screw the inlet connection 3 tightly to the cylinder valve by hand or by using a spanner 3 1 Opening Slowly open the cylinder valve 1 The high pressure gauge 4 will show you the cylinder pressure Opening the cylinder valve too quickly may make gauges malfunction Open the pressure adjusting screw 6 very sl...

Page 4: ...er than the red mark on the low pressure gauge 5 3 3 Closing Close the cylinder valve 1 Release the gas until the regulator gauges indicate zero Turn the pressure adjusting screw 6 anticlockwise till it is completely closed 3 INSTRUCTIONS FOR USE The pressure regulator must be treated as a precision instrument When the pressure regulator is not to be used for long periods store it in its wrapping ...

Page 5: ...or lost The pressure regulator or any of its parts gauge inlet connection outlet connection are damaged or dirty oily etc There are any leaky connections The relief valve adjustment has been modified or the valve leaks 5 2 Relief Valve For safety reasons the pressure regulator is equipped with an excess pressure valve In case of malfunctioning this valve allows the excess gas pressure to vent CAUT...

Page 6: ...on error Release the control knob tighten the connections and re check Apply pressure again if leak persists repair or replace Increase in output pressure when not flowing Leak through the regulator seat valve Replace the encapsulated seat Unstable output pressure Flow rate to high Check the flow of the regulator matches the requirement Vibrations Flow rate to high Limit the flow with the control ...

Page 7: ...7 Note Some of the details in the illustration may differ from those of the appliance supplied This company reserves the right to modify the product without prior warning ...

Page 8: ...he operator in the safe use of a Tesuco Nitrogen 6000 Regulator However the ultimate responsibility for the safe use of this and any attached equipment lies solely with the operator including any requirements of associated Australian Standards OI_RC1SNI60C_V01 ...

Reviews: