TESTO 410-2 Short Manual Download Page 3

Safety and the enviroment

12

Safety and the environment

About this document

>  Please read this documentation through carefully and 

familiarise yourself with the product before putting it to use. 
Keep this document to hand so that you can refer to it when 
necessary. Hand this documentation on to any subsequent 
users of the product.

>  Pay particular attention to information emphasised by the 

following symbols:

 Important.

Avoid personal injury/damage to equipment

>   Only operate the measuring instrument properly, for its 

intended purpose and within the parameters specified in the 
technical data. Do not use force.

>   Never store the product together with solvents, acids or other 

aggressive substances.

>   Only carry out the maintenance and repair work that is 

described in the documentation. Follow the prescribed steps 
when doing so. Use only OEM spare parts from Testo.

>   Do not use the device in a polluted environment (heavily dusty, 

oil, foreign matter, volatile chemicals).

Protecting the environment

>   Take faulty rechargeable batteries as well as spent batteries to 

the collection points provided for them.

>   Send the product back to Testo at the end of its useful life. We 

will ensure that it is disposed of in an environmentally friendly 
manner.

Summary of Contents for 410-2

Page 1: ...Notizen 10 ...

Page 2: ...ing the display light on for 10s Instrument on press Select display size Instrument on select with Velocity humidity wind chill temperature Select display mode Instrument on select with Current reading Hold Readings are held Max Maximum values Min Minimum values Hold Avg Timed mean value calculation see below Timed mean value calculation for flow Press several times until Hold and Avg appear Hold ...

Page 3: ...s intended purpose and within the parameters specified in the technical data Do not use force Never store the product together with solvents acids or other aggressive substances Only carry out the maintenance and repair work that is described in the documentation Follow the prescribed steps when doing so Use only OEM spare parts from Testo Do not use the device in a polluted environment heavily du...

Page 4: ... 4000 fpm 10 50 C 14 122 F 0 100 rH Resolutions 0 1 m s 1 fpm 0 1 C 0 1 F 0 1 rH Accuracies Nominal temperatue 22 C 1 Digit 0 2 m s 2 of reading 40 fpm 2 of reading 0 5 C 0 9 F 2 5 rH 5 95 rH Long term stability 1 rF year Measuring rate 0 5 s humidity 1s Further instrument data Protection class IP10 Ambient conditions 10 50 C 14 122 F Storage transport conditions 40 70 C 40 158 F Temperature coeff...

Page 5: ...on ã Basic settings configuration mode Adjustable functions Unit of temperature C F Unit of humidity td dew point WB wet bulb Unit of velocity m s km h fpm mph kts Beau Auto off function OFF ON instrument switches off automatically if no key is pressed for 10 minutes 1 When switching the instrument on press and hold until and appear on the display configuration mode The adjustable function is disp...

Page 6: ...emperature perceived temperature only deviates from ambient temperature at temperatures 10 C 50 F and wind speeds 1 34m s 264 fpm Press several times until the desired parameter appears ã Changing the display view Adjustable views Current reading Hold Readings are held Max Maximum values since the instrument was last switched on or last reset Min Minimum values since the instrument was last switch...

Page 7: ...ulation hold down 5 End mean value calculation press briefly ã Resetting Max Min values 1 Press several times until the desired view appears 2 Press and hold until appears 3 Repeat steps 1 and 2 for all values that are to be reset ã Switching the instrument off Press and hold until the display goes out ...