TESTING 1.0290 Operating Manual Download Page 15

 
 
Electronic 
Blaine Air-Permeability Apparatus 
1.0290/1.0290E 
 

 

15 

9. 

Spare parts and services 

 
A great deal of care has been taken to ensure that this Operating Manual is correct. We 
cannot,  however,  guarantee  that  it  is  without  mistakes  or  errors,  or  that  all  information 
contained herein will continue to remain valid in the event of technical changes. 
 
 

9.1 

Date of issue of this Operating Manual: 

 

Version no. 11 

Oct. 2016 

 
 

9.2 

Copyright 

 
The copyright to this Operating Manual is held by the following company: 
 

TESTING 

Bluhm & Feuerherdt GmbH 

 
This Operating Manual is provided only for the using company, and the staff of this com-
pany. The information in this Operating Manual may not be: 
 

  Reproduced, or 

  Distributed, or 

  Provided to any other persons. 

 
Any person acting in violation of the above stipulations may be prosecuted before a court 
of law. 
 
 

9.3 

Address for technical support and spare-parts ordering 

 
If you have any technical questions, or if you require spare parts, please get directly in 
touch with the following address:  
 

TESTING Bluhm & Feuerherdt GmbH

 

Motzener Str. 26b 
DE 

– 12277 Berlin 

Germany 
Tel.:  +49 30 (0) 7109645-0 
Fax:  +49 30 (0) 7109645-98 
E-mail:  [email protected] 
www.testing.de 

 

 

Summary of Contents for 1.0290

Page 1: ...Distribution of Systems for the Testing of Construction Materials Motzener Str 26b DE 12277 Berlin Tel 49 30 7109645 0 Fax 49 30 7109645 98 1 Operating Manual Electronic Blaine Air Permeability Appar...

Page 2: ...ns 5 1 6 Acceptance of the product and transport 6 1 6 1 Acceptance of the product 6 1 6 2 Transport 7 1 7 Scope of delivery 7 1 8 Instructions for electrical connection 8 2 Characteristics of the app...

Page 3: ...nition of technically qualified staff has been provided in IEC 364 The User must by all means observe the requirements and limit values as well as all safety instructions given in this Operating Manua...

Page 4: ...with the following actions being taken It may therefore NOT be used under such conditions or in connection with the following actions Do not disassemble this system Do not try to repair it or to modif...

Page 5: ...criteria Persons who are at least eighteen 18 years of age and Persons who have been instructed in the operation of the Blaine Apparatus and In the operation of the Blaine Apparatus the person operati...

Page 6: ...e descriptions given in this Operating Manual all applicable safety directives guidelines and regulations and all general rules for workplace environments The Operator must ensure that the personnel w...

Page 7: ...o the point at which it is to be operated Its weight is approx 4 kg After you have unpacked the device make a visual inspection to determine whether it was damaged during transport In cases of doubt i...

Page 8: ...ystem against overcurrent This device must match the machine voltage and must be in accordance with the valid regulations The technical characteristics of this safety device must satisfy the reg ulati...

Page 9: ...provided by a separate power cable with a two pole and earthing pin plug The Manufacturer tests the function and liquid tightness of the apparatus before delivery 2 2 Technical data Power rating 110...

Page 10: ...the injector hose into the U shaped tube Make sure that you can see the hose in the U shaped tube and also make sure that the manometer liquid actually flows into the tube Fill the liquid up to the lo...

Page 11: ...mps of the oil level indicators will now show consecutively green amber and red The READY lamp will now go off The red lamp will now show which means that the digital counter is set to zero The pump s...

Page 12: ...pparatus from the power supply Use a brush or vacuum cleaner to remove loose dust on the apparatus If neces sary the apparatus can then be cleaned with a moist cloth Use a normal household cleaning ag...

Page 13: ...ctly pump valve is defective The pneumatic lines are loose or have leaks The U shaped tube is covered with condensation or dirt Get in touch with the Supplier Clean the U shaped tube The measured val...

Page 14: ...ase see the diagram below 7 Shutting down the system for lengthy periods If the Blaine Apparatus is scheduled to remain out of operation for a lengthy period of time please follow these steps Disconne...

Page 15: ...llowing company TESTING Bluhm Feuerherdt GmbH This Operating Manual is provided only for the using company and the staff of this com pany The information in this Operating Manual may not be Reproduced...

Reviews: