background image

85641 

Rev 1 

Dec 2016 

Quick Guides 

MPQ1000 

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for Megger MPQ1000

Page 1: ...85641 Rev 1 Dec 2016 Quick Guides MPQ1000 M 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Page 2: ...uate for the intended use of the product If the product or its individual instruments are used for purposes other than those specified herein confirmation of their validity and suitability must be obtained from Megger Refer to the warranty information below Specifications are subject to change without notice ...

Page 3: ...of Contents MPQ1000 Quick Guide Instructions ENGLISH 1 Instructions relatives au Guide rapide MPQ1000 FRANÇAIS 7 MPQ1000 Kurzanleitungen DEUTSCH 15 Guía Rápida para el usuario del analizador MPQ1000 Instrucciones de Uso Español 23 ...

Page 4: ...85641 Rev 1 Dec 2016 ii M ...

Page 5: ...85641 Rev 1 Dec 2016 1 MPQ1000 Quick Guide Instructions English ...

Page 6: ...lp Button 6 Record Button 7 Scope Mode 8 DMM Mode Powering Up the Unit Powering the analyzer Plug the Power Adapter to the analyzer Plug the Power Adapter into an AC Outlet NOTE If the recording being performed is just a few hours then the analyzer can be run off batteries Be sure the analyzer battery is fully charged Power On Press the power ON button The unit boots up to the DMM mode Real Time S...

Page 7: ...the l left right arrow and Enter key to scroll through the different screens Configuring Analyzer Main Menu Press the MENU button to go to the main menu Select a Setup File Configuration From the Main Menu select SETUP From the Setup Menu select SELECT Select the desired unit configuration file ...

Page 8: ...ognition The unit will verify it is connected correctly and let you know if anything is connected wrong Stop Recording Press the Record button to stop the recording View Data Main Menu Press the MENU button to go to the main menu Select View Data From the main menu select VIEW DATA Select desired data file Select type of data to view ...

Page 9: ...v 1 Dec 2016 4 Analyze Data Main Menu Press the MENU button to go to the main menu Select data file and template From the main menu select ANALYZE Select the desired data file Select the desired analysis template ...

Page 10: ...er PQ Software select FILE IMPORT SD CARD TO PQ Transfer to USB Stick Insert SD Card into MPQ Analyzer From the main menu select USB Select EXPORT TEST DATA TO USB Insert USB Stick into PC Select FILE IMPORT TRANSFER USB TO PQ Transfer via USB Connect Analyzer to PC via USB cable In Megger PC select CONFIG COMMUNICATIONS ...

Page 11: ...641 Rev 1 Dec 2016 6 Select USE COM PORT Click on VERIFY CONNECTION Click on DOWNLOAD 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...