4
International Electronic/Service Vacuum
Operating Instructions
To Store Attachments
for Transport
To Replace Filter
1. Unplug the power cord from the
outlet and the vacuum.
2. Open the lid and retrieve the L-15X
filter plug.
3. Remove the hose from the inlet and
insert the L-15X filter plug.
4. Detach the hose nozzle from the base.
5. Place the hose, power cord and
attachments into the lid and close the
accessory door.
6. Close the lid and securely fasten the
latches.
The Vacuum is designed for use with
disposable Filters. The Filters must be
replaced on a regular basis. Frequency
of filter replacement
depends on the
type and frequency of use of the
Service Vacuum.
1. Release the latches and open the lid.
2. Remove either the L-15X filter plug
or hose. Save the plug for use later
(see note below).
3. Grasp the filter and pull it straight up
4. Insert the L-14X filter plug in the
filte .
5. Dispose of the filter in a suita le
manner.
6. Remove the L-14X plug from the new
filter and position filter in the acuum
with the filter hole to our left. Save
the L-14X plug for use in disposing
the filter (see note bel w).
7. Verify that the gasket between the
filter and the motor fits tigh y.
8. Insert the L-15X filter plug or hose
9. Close and latch the lid.
Note: The L-15X plug (longer plug) is
used to cover the filter inlet for storage
when the vacuum cleaner is not in use.
This plug comes with the filter in a
new vacuum cleaner. The L-14X plug
(shorter plug) is used to cover the filter
inlet for disposal. This plug comes with
each new replacement filte .
ELECTRIC SHOCK COULD
OCCUR IF USED OUTDOORS
OR ON WET SURFACES!
Do not operate when filter
is full. A lack of suction or
exhaust is an indication of a
full filter.
To avoid risk of fire, filter
must be installed properly
and replaced regularly. Do
not open filter, reuse filter or
attempt to replace components
within filter.
WARNING
!
CAUTION
!
CAUTION
!