CEC-78K0R/KG3 USER'S MANUAL
4. DDC Monitor
DDC data can be monitored on GUI by setting SSW24[DDC MONITOR] switch to ON.
4.1 Monitoring DDC on GUI
No special process is needed to monitor DDC on GUI.
Like CEC monitoring, click shortcut key
to start monitoring. It monitors both CEC and
DDC data.
Row with
means that it is DDC data.
Row with
means that it is CEC data.
As the data format, it stores data on odd number rows and ACK/NACK on even number rows.
When it detects the Start Condition, it recognizes as the next data.
(Also, in the case of restarting that it does not get Stop Condition, it recognizes as the next data)
DDC
Data
CEC
Data
TESSERA TECHNOLOGY INC.
31/31