background image

Tesla

 TI5679 MPU-24 

User Manual

Built Smart...Proven Tough

Power Anytime, Anywhere

Tesla Industries, Inc.

101 Centerpoint Blvd.

New Castle, DE 19720

(302) 324-8910 Phone

(302) 324-8912 Fax

www.teslaind.com 

www.tesla1.com

Summary of Contents for TI5679 MPU-24

Page 1: ...TI5679 MPU 24 User Manual Built Smart Proven Tough Power Anytime Anywhere Tesla Industries Inc 101 Centerpoint Blvd New Castle DE 19720 302 324 8910 Phone 302 324 8912 Fax www teslaind com www tesla1...

Page 2: ...e opened or disassembled for any reason Always protect the unit from short circuit Shipping Hazards The unit contains sealed dry cell rechargeable batteries that do not pose a shipping hazard All Grou...

Page 3: ...oors or in a well ventilated area Causes damage to central nervous system blood and Contact with internal components may cause irritation or severe burns Avoid contact with internal acid kidneys throu...

Page 4: ...bicarbonate lime etc Wear acid resistant clothing boots gloves and face shield Do not allow discharge of unneutralized acid to sewer Acid must be managed in accordance with local state and federal req...

Page 5: ...2 7 Press for Capacity Button and LED Status Indicator 7 2 8 Maintenance Check 8 2 9 Pre Installation Procedures 8 Section 3 Operating Procedures 9 3 1 Operating Procedures 9 3 2 General 9 3 3 Operat...

Page 6: ...ackaging and Shipping 21 Section 6 Troubleshooting and FAQ 22 24 Section 7 Performance Data 25 7 1 Purpose 25 7 2 General 25 7 3 Data Basis 25 7 4 Specific Conditions 26 7 5 General Conditions 26 7 6...

Page 7: ...nheit dc Direct Current EFF Efficiency ft Feet FWD Forward GPU Ground Power Unit Hr Hour Hz Hertz kg Kilograms kHz Kilohertz kW Kilowatts LED Light Emitting Diode max Maximum M megaohm min Minimum MPU...

Page 8: ...WARNING Indicates a condition operating procedure or practice which if not adhered to could result in serious injury or death CAUTION Indicates a condition or operating procedure which if not strictl...

Page 9: ...r Ground Adapter with Grounding Mechanism Secured to Outlet Figure 1 3 3 Improper Ground Plug with No Grounding Pin The use of unapproved ac power will damage the unit Check the Input Voltage Selector...

Page 10: ...l support for ground maintenance avionics electrical trouble shooting and testing The observance of procedures limitations and performance criteria ensures peak operating efficiency and maximizes oper...

Page 11: ...5 C AC Input Operates and charges from single phase 100 260 Vac 45 450 Hz 5 5 amps single phase 120 Vac 2 75 amps single phase 240 Vac Physical Properties 15 57 long x 10 345 wide x 9 5 high 395 5 mm...

Page 12: ...ently regulate unit temperature regardless of load At room temperature 77 F the exhaust air will not exceed the ambient temperature by more than 5 F In more extreme temperatures greater than 90 F the...

Page 13: ...n The TI5679 MPU 24 should be operated in the horizontal position as shown Figure 2 7 1 Make sure that the airflow is not obstructed from outlet Figure 2 7 2 and air intake Figure 2 7 3 Figure 2 7 2 F...

Page 14: ...Push to Test button on the faceplate 2 and hold for approximately 2 to 3 seconds The LED bar graph should light up indicating the status of the power cells 3 In addition the fan s should start operat...

Page 15: ...raft s operator manual procedures to remove and dispose of the original aircraft battery properly and safely Once the original battery has been removed from the battery compartment proceed to the next...

Page 16: ...ional checks of the unit Knowledge of the operating limits restrictions performance unit capabilities and functions is fundamental to correct and safe operation The operator shall ensure compliance wi...

Page 17: ...s may damage the unit If the unit is operated when cold or heat soaked temperatures are exceeded a full functional check should be accomplished prior to continued use NOTE ENGINE START PEAK CURRENT Re...

Page 18: ...e the unit into a cooler climate such as shade or air conditioning when possible Perform a full function test prior to use after the unit has been allowed to cool 3 6 Temperature Specifications Cold H...

Page 19: ...l be taken to A Prevent accumulation of moisture on ac and dc connectors receptacles B Minimize moisture entering forward inlet and outlet cooling fan vent ports When not in use unit inlet and outlet...

Page 20: ...capable of measuring dc and ac voltage and resistance will be required to perform some of the tests These functional test procedures should become routine Figure 3 9 1 Digital Multimeter Check Unit f...

Page 21: ...Figure 3 9 3 Next place the negative probe on the negative post The multimeter display should read approximately 28 5 Vdc 0 5 Vdc when power cells are fully charged and the unit is plugged into an ac...

Page 22: ...en the unit is plugged into ac power the output is 28 5 volts This voltage allows the system to recondition and recharge the aircraft s battery ies It is also an optimum voltage for powering avionics...

Page 23: ...rcraft ground power receptacle DC bus power should come on and aircraft voltmeter should indicate 28 5 Vdc to 23 5 Vdc 23 Vdc minimum If current demand is greater than 10 amps converter output voltage...

Page 24: ...3 inches of clearance in the front of the Air Exhaust Fan to provide for sufficient ventilation If the unit is completely discharged a minimum of 281 minutes will be required to fully recharge the un...

Page 25: ...ed button 4 Reconnect ac and dc connections to the unit Plug in ac line cord on military unit The unit should power up automatically If the breaker continues to trip return the unit to Tesla Industrie...

Page 26: ...lls become fully discharged the unit should be recharged within 24 hours to ensure maximum life and performance Under normal circumstances a minimum of 281 minutes will be required to fully recharge t...

Page 27: ...eriodically with a soft cloth to remove dust dirt etc Protect Cables from Damage Do not cut crush or drag the input or output power cables when handling the TI5679 MPU 24 Always inspect cables prior t...

Page 28: ...Customer Service at 302 324 8910 with any questions or concerns TESLA INDUSTRIES INCORPORATED 101 CENTERPOINT BLVD CENTERPOINT INDUSTRIAL PARK NEW CASTLE DELAWARE 19720 PHONE 302 324 8910 FAX 302 324...

Page 29: ...re you travel ensuring that you will always have power 4 How much power will my Turbo Start provide Depending on the system the TI5679 MPU 24 will provide anywhere from 10 continuous to 3000 peak star...

Page 30: ...ain 80 of their capacity after one year of storage 12 How do I get my Turbo Start serviced Contact Tesla at 302 324 8910 Ask for customer service You can also email us at tesla1 teslaind com Once we r...

Page 31: ...on ensures proper and consistent ventilation of the unit 6 Why does the cooling fan slow down Cooling fan rpm varies for better temperature regulation 7 Why does my LED flicker when the unit is plugge...

Page 32: ...tions under unfamiliar conditions or environmental extremes The data may also be used to establish local operating procedures and to ensure unit s operational life is maximized NOTE 7 2 General The da...

Page 33: ...rformance will be given 7 5 General Conditions In addition to the specific conditions the following general conditions are applicable to the performance data Variation in Aircraft Power demand differe...

Page 34: ...8 13 0 8 6 20 0 68 0 53 0 127 4 45 0 49 0 12 0 10 4 21 0 69 8 54 0 129 2 44 0 47 2 11 0 12 2 22 0 71 6 55 0 131 0 43 0 45 4 10 0 14 0 23 0 73 4 56 0 132 8 42 0 43 6 9 0 15 8 24 0 75 2 57 0 134 6 41 0...

Page 35: ...700 2400 5 10 15 20 25 30 25 C Temp 29 C Temp Calculations based on actual test data at Pratt Whitney Canada on 30 March 1992 SECONDS AMPS MAXIMUM OUTPUT CURRENT 0 0 TI5679 MPU 24 Maximum Output Curre...

Page 36: ...Line Cord TI25000 005 England UK Line Cord TI25000 006 Swiss Line Cord TI25000 011 Australian Line Cord TI25000 200 Israel Line Cord TI25000 300 Denmark Line Cord For units with a fuse and old style r...

Page 37: ...n Line Cord Burma Now Myanmar 230 50 TI25000 005 United Kingdom Line Cord Burundi 220 50 TI25000 003 Continental European Line Cord Cambodia 220 50 TI25000 003 Continental European Line Cord Cameroon...

Page 38: ...Guadeloupe 220 50 TI25000 003 Continental European Line Cord Guam 110 120 60 TI25000 001 North American Line Cord Guatemala 120 60 TI25000 001 North American Line Cord Guinea 220 50 TI25000 003 Conti...

Page 39: ...Line Cord Montseurrat 230 60 TI25000 005 United Kingdom Line Cord Morocco 220 50 TI25000 003 Continental European Line Cord Mozambique 220 50 TI25000 003 Continental European Line Cord Namibia W S Afr...

Page 40: ...00 004 Old British Line Cord Sweden 220 50 TI25000 003 Continental European Line Cord Switzerland 220 50 TI25000 006 Switzerland Line Cord Syria 220 50 TI25000 003 Continental European Line Cord Tahit...

Page 41: ...00 19 AND MUST BE ORDERED WITH THE ORIGINAL PROCUREMENT OF UNIT S UNIT S MAY BE RETURNED TO TESLA INDUSTRIES FOR A NOMINAL COST AND MODIFIED TO ALLOW OPERATION WITH THE UNIVERSAL AC LINE CORD KIT TESL...

Page 42: ...ail _______________________________________________________________________________________ Purchase Order ______________________________________________________________________________ Model ________...

Page 43: ...TI1000 Tesla 101 Centerpoint Blvd New Castle DE 19720 USA Tel 302 324 8910 Fax 302 324 8912 9475 Double R Blvd Suite 2 Reno NV 89521 Tel 775 622 8801 Fax 775 622 8810 www teslaind com www tesla1 com...

Reviews: