NOV.2009.5,000(P)
R
8. INPUT RANGE TABLE
N
N
N
N
0
0
0
to
to
to
400
1000
1300
A4
A0
B3
N
0
to
800
A8
R
0
to
1750
B8
S
S
0
to
1000
A0
S
S
0
0
to
to
1600
1750
B6
B8
2 to 10VDC
V
A
A
09
03
02
4 to 20mA
0 to 20mA
or
to 9.999
-1.999
(*1) 0 to 400
: Accuracy is not guaranteed.
C
(*2)This input type can not be selected by keyboard. Because the hardware of the inputs
are different.
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*2
*2
*1
*1
K
K
K
K
K
K
K
K
0
0
0
0
0
0
0
to
to
to
to
to
to
100
200
400
600
1000
1300
1350
A1
A2
A4
A6
A0
B3
B4
K
0
to
800
A8
to
J
J
J
J
J
J
0
0
0
0
0
to
to
to
to
100
200
300
400
600
A1
A2
A3
A4
A6
J
J
0
0
to
to
800
1000
A8
A0
to
B
B
50
to
1300
B3
B
50
to
1800
B8
R
R
R
0
0
to
600
1000
A6
A0
R
0
to
1300
B3
to
0
0
to
to
800
1000
A8
A0
E
E
E
E
E
E
E
E
E
0
0
0
0
0
0
to
to
to
to
to
100
200
300
400
500
600
A1
A2
A3
A4
A5
A6
to
T
T
T
T
0
0
0
0
to
to
to
100
200
300
400
A1
A2
A3
A4
to
T
T
T
T
0
0
0
to
to
to
1600
2000
2300
B6
B0
C3
W5Re/
W26Re
C
C
C
0.0
to
to
to
50.0
100.0
150.0
D5
D1
D2
0.0
0.0
C
C
-50.0
to
to
+50.0
+100.0
C5
C1
-50.0
C
-50.0
to +150.0
C2
CU50
Pt100
D
D
D
D
0.0
to
to
to
to
100.0
200.0
300.0
400.0
D1
D2
D3
D4
0.0
D
D
to
to
500.0
600.0
D5
D6
0.0
0.0
D
D
D
to
to
to
+200.0
+100.0
+100.0
E2
F1
E1
-199.9
-100.0
-199.9
D
to +200.0
F2
-100.0
0.0
0.0
D
to +50.0
G0
-50.0
D
D
D
to
to
to
+100.0
+600.0
+200.0
G1
E6
G2
-50.0
-199.9
-50.0
0 to 5VDC
0 to 10VDC
1 to 5VDC
V
03
V
V
04
08
to 9999
-1999
or
to 99.99
-19.99
to 999.9
-199.9
or
Overscale and Underscale
Error display
Requirements for AT start
Autotuning (AT) start
Requirements for AT cancellation
7.ERROR DISPLAYS
!
To prevent electric shock, always turn
off the power before replacing the
sensor.
M e a s u r e d v a l u e ( P V )
[ F l a s h i n g ]
PV is outside of input range
Overscale:
PV is above the high input display range limit.
RAM failure(Incorrect set date write or check sensor and
sensor connection,etc.)
Underscale:
PV is below the low input display range limit.
WARNING
[ F l a s h i n g ]
[ F l a s h i n g ]
[ F l a s h i n g ]
Check input type, input range, sensor
and sensor connection..
Turn off the power once. If an error occurs
after the power is turned on again, please
contact TESHOW sales office or the agent.
6
PID AUTOTUNING (AT) FUNCTION
Autotuning (AT) automatically measures, calculates and sets the
optimum PID. The following conditions are necessary to carry out
autotuning and the conditions which will cause the autotuning to
stop.
Start the autotuning when all following conditions are satisfied:
(1) Prior to starting the AT function, end all the parameter settings
other than PID.
(2) Confirm the LCK function has not been engaged.
The autotuning is canceled if any of the following conditions exist.
(1) When the
is changed.
(2) When the power is turned off.
(3) When power failure longer than 20ms occurs.
parameter "AT " value
When the autotuning is finished, the controller will
automatically return to PID control.
Caution for using the Autotuning (AT)
When a temperature change(UP and/or Down) is 1 or less
per minute during Autotuning, Autotuning may be cancelled
before calculating PID values. In that case, adjust the PID
If the AT is canceled, the controller immediately changes to
PID control. The PID values will be the same as before AT
was activated.
When AT is completed, the controller immediately changes to
PID control. If the control system does not allow the AT cycling
process, set each PID constant manually to meet the needs of
the application.
values manually. It is possible to happen when the set value
is around the ambient temperature or is close to the maximum
temperature achieved by the load.
1) Press the "SET" key for 3 seconds to PID level.
2) Looking for the parameter "AT ".
3) Set "AT" value from 0 to 1.
4) Press the "SET" key start auto tuning.
5) Press the "SET" key for 3 seconds to return to
(If AT be started ,the AT lamp will be lighted on and the lamp is
flashing)
the instrument to
the PV/SV display mode.
ON
OFF
ON
OFF
PV
PV
SV
Time
100%
0%
Output %
ON/OFF control
(Autotuning)
PID control
(After autotuning
6
TS80B-E1
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Input type
Code
Code
Code
Code
Code
Code
Code
Code
Code
Code
Code
Code
AN THAI CORPORATION
TESHOW ELECTRONIC TECHNOLOGY CO., LTD.