Digital PID Controller

                                                      

TS80B-E1

C a r e f u l l y   r e a d  a l l   t h e  i n s t r u c t i o n s   i n  t h i s   m a n u a l .  P l e a s e   p l a c e
t h i s   m a n u a l  i n   a  c o n v e n i e n t   l o c a t i o n  f o r   e a s y  r e f e r e n c e .

W A R N I N G

CAUTION

(4) Control output [OUT]:

        M:Relay contact                             V: Voltage pulse

        8: Current(DC4 ~ 20 mA)              5: DC0-5VDC

        6: DC0-10VDC                               T: Trigger (for triac driving) 

 (5) Remark:

        N: No                      

(6) Alarm 1[AL1 for high alarm]     See"5.5 

"

        N:  No alarm

        A:  Deviation high alarm                H: Process high alarm

(7) Alarm 2[AL2 for low alarm]      See"5.5 

"

        N:  No alarm

        B:  Deviation low alarm                J: Process low alarm 

(8) Power

        A: 220VAC      B

85-265VAC         D

24VDC             E

24VAC                                       

Initial Setting 

Initial Setting 

!

TS80B-E1

INSTRUCTION MANUAL

1

 An external protection device  must  be  installed if failure  of   this

   instrument could result in damage  to  the instrument,  equipment
   or injury to personnel                                 .                                                                       

 All wiring must be completed before power in turned on to prevent

   electric shock, fire or damage to instrument and equipment    .  

 This   instrument    must   be    used    in    accordance    with    the 

   specifications   to   prevent    fire   or   damage   to instrument and 
   equipment.

 This  instrument  is  not intended  for  use  in  locations  subject to 

   flammable or explosive gases.

 Do not touch  high-voltage   connections   such  as  power  supply 

   terminals , etc. to avoid electric shock.

 This  instrument  is  protected   from   electric   shock by reinforced

   insulation.   Provide   reinforced   insulation   between  the  wire for 

   the  input signal and the wires for instrument power supply,  source 

   of power and loads.

 This     instrument     is    design   for   installation in   an    enclosed 

   instrumentation panel.   All  high-voltage   connections   such    as   

   power  supply  terminals must be  enclosed in the  instrumentati on 

   panel to avoid electric shock by operating personnel.

 All precautions described in this  manual should be  taken  to  avoid

   damage to the instrument or equipment.

 All wiring must be in accordance  with  local  codes and regulations.

 

 

 

 

 

 

 

 

Always      observe     precautions      described     in     this manual.      

  Otherwise serious injury or accident may result.

Do not allow metal fragments or  lead  wire scraps  to fall inside this  

   instrument. This may cause electric shock, fire or malfunction.

Firmly tighten  each  terminal    screw   at   the    specified    torque. 

   Otherwise electric shock or fire may result.

Do  not   place  any  obstacle  around  this    instrument    in    order  

   not  to  impede radiation of heat. And do not close ventilation holes. 

Do not connect wires to unused terminals.

Before cleaning the instrument, always  turn off   the  power supply.

Remove stains from this instrument using a soft, dry cloth.  Do  not 

   use a volatile solvent such as thinner in order to avoid deformation 

   or  discoloration.

Do not rub nor strike the  display unit  of  this instrument with a hard 

   object.

             -                    

1. PRODUCT CHECK

             -                    

(1) Control action

        F: PID reverse action with autotuning

        

        

(1) (2)

(3)

(4) (5)

(6) (7)

(8)

(2) Input type,(3)  Range code: See"8.INPUT RANGE TABLE"   

                                                     
         Check  MODEL and CODE
is very important when ordering.

2.1 Mounting Cautions

2. MOUNTING 

(1) Use    this     Instrument    within     the     following     ambient
         temperature and ambient humidity.

 Allowable ambient temperature: 0 to 50
 Allowable ambient humidity: 45 to 85% RH

(2) Avoid the following when selecting the mounting location.

 Rapid changes in ambient temperature which may cause condensation.
 Corrosive or inflammable gases.
Direct vibration or shock to the mainframe.
Water,oil,chemicals,vapor or steam splashes.
Excessive induction noise, static electricity, magnetic fields or noise.
Direct air flow from an air conditioner.
Exposure to direct sunlight.
Excessive heat accumulation.

 

C

TS81B/TS84B/TS85B/TS87B/TS89B

TS85B

TS84B

TS89B

TS87B

TS81B

                             

Example

 Model: TS89B         

 Specification:

 

Model of the controller:TS89B

  

Size: 96mm x 96mm 
Control action: PID reverse action
Input: K type thermocouple
Out put: Relay output
Alarm: 1 deviation high alarm (AL1)
Power: AC220V

 Code: FKA4-MN*AN-A

2.2  Dimensions

TS81B

50

14.6

5

0

4

4

.0

4

4

.0

5

8

.0

80

13.6

1

1

TS84B
TS85B

50

14.6

9

6

4

4

.0

9

0

.0

1

0

4

.0

80

13.6

1

1

74

14.6

7

4

6

7

.5

6

7

.5

8

0

.0

80

13.6

1

1

UP

TS87B

TS89B

9

0

96

14.6

9

6

9

0

.0

1

0

4

.0

80

13.6

1

1

UP

 Unit:mm

 Unit:mm

 Unit:mm

 Unit:mm

Reviews: