T-200 Series UPS User Manual 

1

 

I. SAFETY 

 
This manual contains important instructions for T-200 series UPS that should be followed during 
installation and maintenance. 

 

IMPORTANT NOTICES 

 

1. 

Read instructions carefully before operating the UPS 

 

2. 

All warnings in the manual should be adhered to. 

 

3. 

All operating instructions should be followed. 

 

4. 

The unit should be supplied by a grounded outlet. Do not operate the unit without ground source. 

 

5. 

Power cord of the UPS should be routed carefully so that they are not to be walked on. 

 

6. 

Please save this manual. 

 

7. 

Please save or recycle the packaging materials. 

 

WARNING! 

 

 

Do not insert any object into ventilation holes or other openings. 

 

To reduce the risk of fire or electric shock, install in temperature and humidity controlled indoor 
area free of conductive contaminants.  

 

To reduce the risk of fire, replace fuses with the same type and rating when necessary. 

 

CAUTION! 

 

 

Only qualified personnel should install or service UPS/batteries.

 

 

 

Risk of electric shock, do not remove cover. No user serviceable parts inside, refer 
servicing to qualified service personnel.

  

 

 

The output may be energized when the unit is not connected to a mains supply. 

 

 

Risk of electric shock hazardous live parts inside this unit are energized from the battery 
supply even when the input AC power is connected.

 

 

 

To reduce the risk of electric shock, disconnect the UPS from the mains supply before installing a 
computer interface signal cable. Reconnect the power cord only after signalling interconnections 
have been made. 

 

ABOUT THE BATTERY  

 

 

A battery can present a risk of electric shock or burn from high short circuit currents. The 
following precaution should be observed when working on batteries : 

 

 

 

 

* Remove watches, rings or other metal objects. 

 

 

* Use tools with insulated handles. 

 

The  batteries  in  this  UPS  are  recyclable.  Batteries  must  be  disposed  of  according  to  local 
environmental laws. The batteries contain lead and pose a hazard to the environment and human 
health if not disposed of properly.  

 

 

Do  not  dispose  of  batteries  in  a  fire.  The  batteries  will  explode.  Do  not  open  or  mutilate  the 
batteries.  They  contain  an  electrolyte  which  is  toxic  and  harmful  to  the  skin  and  eyes.  If 
electrolyte comes into contact with the skin the affected area should be washed immediately. 

 

 

The internal energy source (the battery) cannot be de-energized by the user.  

 

Summary of Contents for T-200 Series

Page 1: ...USER MANUAL T 206 6 kVA T 207 7 5 kVA T 210 10 kVA T 200 SERIES UNINTERRUPTIBLE POWER SUPPLIES 3 Phase Input 1 Phase Output...

Page 2: ......

Page 3: ...rupted 9 4 4 Operator Control Panel 9 4 4 1 Push Buttons 10 4 4 2 First Message Line Of The LCD 10 4 4 3 Second M L ALARMS Of The LCD 11 4 5 Automatic Battery Test System optional 11 V OPTIONAL EQUIPM...

Page 4: ...ed service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply eve...

Page 5: ...wave output PWM and IGBT technology Microprocessor controlled main controller board Static STS and maintenance by pass LCD Liquid Crystal Display display Alarm history Memory for max 64 alarms Automa...

Page 6: ...of power transistor IGBT and pulse width modulation PWM Inverter converts dc bus voltage into an alternative voltage like line voltage And provides this voltage and frequency being fixed Static Trans...

Page 7: ...Voltage 220 230 240 VAC Output Voltage Tolerance 1 Output Frequency 50 Hz Output Frequency Tolerance Line Synchronized 1 Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 1...

Page 8: ...Figure 2 2 1 6 7 5 10 kVA Rear view 6 7 5 10 kVA Model S Rear view Battery Fuse AC Output Terminals DB9 Port PK1 On Off Switch AC Output 6 7 5 10 kVA Model A Rear view Battery Fuse DB9 Port PK1 On Off...

Page 9: ...Optional 3 2 Location Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended...

Page 10: ...tected by a circuit breaker 1 Before connecting AC and DC power to the UPS make sure that the On Off Switch PK1 Main Switch and battery fuse on the rear panel are in the 0 position OFF 2 Connect the A...

Page 11: ...audible alarm will sound intermittently Now the output receptacles are supplied from the battery source 4 Connect the power again and see that LINE FAILURE alarm is off 5 Now your UPS is ready to oper...

Page 12: ...cords into outlets 4 3 When Utility Power Is Interrupted In case the utility power is interrupted the UPS converts the built in battery source to output terminals immediately to protect your critical...

Page 13: ...s message the sound button enables disables sound alarm SOUND ON SOUND OFF Audible alarm is active Audible alarm is not active disabled by the user Each press to this button will change the status BAT...

Page 14: ...out of tolerance ONLINE MODE UPS operating mode is ONLINE mode ECONO MODE optional This message shown the alternate operating mode is active OFFLINE 4 5 Automatic battery test system optional There ar...

Page 15: ...unicate so that the computer system is warned of impending UPS shutdown Software T MON RUPS RUPSII UPSILON 2000 and SNMP devices is available for most operating systems and is supplied with a signalin...

Page 16: ...ftware supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate Software that communicates with SNMP m...

Page 17: ...system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LAN...

Page 18: ...T 200 Series UPS User Manual 15...

Page 19: ...T 200 Series UPS User Manual 16 Connection Diagram Of The RMP COM1 T MON...

Page 20: ...iced only by authorized people In case of a persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the s...

Page 21: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited t...

Page 22: ...AGKK3802 09 2013...

Reviews: