background image

 

- 8 - 

7.    Problems and interference with operation 

 

Problem & cause 

Remedy   

Distance between the transmitter and 
receiver too long 

Reduce distance between the transmitter and receiver to 
receive signal 

High  shielding  materials  between  the 
units  (thick  walls,  steel,  concrete, 
isolating aluminum foil, etc.) 

Find a different location for sensor and/or receiver. See also 
item ‘transmission range’ below 
 

Interference  from  other  sources  (e.g. 
wireless radio, headset, speaker, etc. 
operating on the same frequency) 

Find a different location for the sensor and/or base station. 
Neighbors using electrical devices operation on the same signal 
frequency can also cause interference with reception 

No  reception  after  adding  extension 
cables 

Find a new location for the sensor and/or base station.   

Poor contrast LCD or no reception or 
low batteries in sensor or receiver 

Change batteries ( check low battery indicator on the LCD) 

Temperature, humidity, or air pressure 
is incorrect. 
 
 

Check/replace batteries. If multiple remote sensors are in use, 
check  location  with  corresponding  “boxed  numbers”.  Or  move 
away from sources of heat/cold. Adjust relative air pressure to a 
value from a reliable source (TV radio, etc.).   

 

 
8. Specifications 

 

Outdoor data 

Transmission distance in open field   

:    100 meters max.   

Frequency 

:    433MHz   

Temperature range 

:    -40 

o

C to +65 

o

C (show OFL if outside range) 

Resolution 

:    0.1 

o

Measuring range rel. humidity 

:    20%

̚

95%   

Humidity accuracy 

:    +/-5% under 0-45 

o

Measuring interval thermo-hygro sensor 

:    48 sec 

Water proof level 

:    IPX3 

 

Indoor data 

Pressure / temperature 

:    48 sec 

Indoor temperature range 

:    0 

o

C to +60 

o

C   

Resolution 

:    0.1 

o

Measuring range rel. humidity 

:    1% ~ 99% 

Resolution 

:    1% 

Measuring range air pressure 

:    700hPa – 1100hPa 

Resolution/Accuracy 

:    0.1hPa/1.5hPa 

Alarm duration 

:    120 sec 

 

Power consumption 

Base station 

:    3 x AA 1.5V LR6 Alkaline batteries 

Remote sensor 

:    2 x AAA 1.5V LR03 Alkaline batteries 

Battery life 

:    Minimum 12 months for base station 

 

:    Minimum 24months for remote sensor 

Summary of Contents for WS1151

Page 1: ...n listing 7 7 Problems and interference with operation 8 8 Specification 8 This Operation Manual is part of this product and should be kept in a safe place for future reference It contains important notes on setup operation and resetting when necessary NOTE Thank you for purchasing this Wireless Weather Station This is a combined operation manual for WS1151 Designed for everyday use the weather st...

Page 2: ...oor sensor data received 4 Mount the units ensuring that the receiver can still pick up the signal from the transmitter To measure outdoor temperature place the transmitter less than 100 meters outdoors It will transmit the temperature from its location Every time the remote sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be syn...

Page 3: ...desired location by the hanging holes also at the back of the unit It is important to check that the radio signal can be received before permanently mounting any of the units 3 Remote sensor 4 Note To achieve a true temperature reading avoid mounting remote sensor in direct sunlight We recommend that you mount the remote sensor on an outside South facing wall obstacles such as walls concrete and l...

Page 4: ...t Quarter Last Quarter Waxing Gibbous Waning Gibbous four weather icons Sunny partly Cloudy Cloudy and Rainy represent the weather forecasting There are also two weather tendency indicators to show the air pressure tendency between the weather icons The weather forecasting is based upon the change of air pressure 4 3 Weather tendency indicator The weather tendency indicators arrow is located betwe...

Page 5: ... press the MIN MAX key or key shifts the display between outdoor temperature and dew point 2 Absolute pressure Relative pressure press the MIN MAX key or key shifts the display between the absolute pressure and relative pressure Press the SET key to accept the change and advance to the next display mode Continue to press the SET key to toggle through the display mode until return to the normal Mod...

Page 6: ...r off if alarm is enabled the speaker icon on the LCD will be turned on indicating the alarm function has been enabled Press the SET key to confirm the setting and continue pressing the SET key to toggle through each alarm mode until it returns to the normal display mode Press SNOOZE LIGHT key or key idle 10 second at any time the alarm mode will return to Normal Mode Canceling the Temperature Ala...

Page 7: ...nimum 2 Indoor temperature minimum 3 Outdoor humidity minimum 4 Outdoor temperature minimum 5 Outdoor dewpoint minimum 6 Pressure minimum While in the minimum or maximum mode press SET key for 2 seconds individual minimum or maximum record will be reset to current reading together with the current time and date Press the SNOOZE LIGHT key or key idle 10 seconds the Min Max mode will return to Norma...

Page 8: ...ttery indicator on the LCD Temperature humidity or air pressure is incorrect Check replace batteries If multiple remote sensors are in use check location with corresponding boxed numbers Or move away from sources of heat cold Adjust relative air pressure to a value from a reliable source TV radio etc 8 Specifications Outdoor data Transmission distance in open field 100 meters max Frequency 433MHz ...

Reviews: