TES TES-593R Instruction Manual Download Page 1

 

ELECTROSMOG METER 

TES-593R 

INSTRUCTION

 

MANUAL 

Z

Y

X

AVG

MAX

2

 

TES ELECTRICAL ELECTRONIC CORP.

 

Summary of Contents for TES-593R

Page 1: ...ELECTROSMOG METER TES 593R INSTRUCTION MANUAL Z Y X AVG MAX 2 TES ELECTRICAL ELECTRONIC CORP...

Page 2: ......

Page 3: ...RATION 8 4 1 Front panel controls description 8 4 2 LCD display description 11 4 3 Use E field sensor 13 4 4 Explanatory notes 13 4 5 Setting the meter 16 4 6 Making measurements 22 4 7 Manual data me...

Page 4: ...e vicinity of powerful radiation sources can be a risk of your life Be aware that persons with electronic implants e g cardiac pacemakers are subject to particular dangers in some cases Observe the lo...

Page 5: ...n This Meter used to indicate electromagnetic pollution generated artificially Wherever there is a voltage or a current the electric E and magnetic H fields arise All types of radio broadcasting and T...

Page 6: ...quare centimeter mW cm2 The characteristic of electromagnetic fields Electromagnetic fields propagate as waves and travel at the speed of light c The wavelength is proportional to the frequency wavele...

Page 7: ...nnel are not exposed to dangerous levels of electromagnetic radiation such as High frequency RF electromagnetic wave field strength measurement Mobil phone base station antenna radiation power density...

Page 8: ...measure of the power absorbed by a person exposed to the field This power level must be kept as low as possible at high frequencies The meter can be set to display the instantaneous value or the maxi...

Page 9: ...alue Instantaneous measured value maximum value or maximum average value Alarm function Adjustable threshold with ON OFF Calibration factor CAL Adjustable Manual data memory and read storage 99 data s...

Page 10: ...sor type Electrical field E Frequency range 10MHz to 8GHz Specified measurement range CW signal f 10MHz 20mV m to 108 0V m 53 A m to 286 4mA m 1 W m2 to 30 93W m2 0 W cm2 to 3 093mW cm2 Dynamic range...

Page 11: ...1 Front panel controls description Z Y X AVG MAX 2 1 E field sensor 2 LCD display 3 key Press this key to turn the meter on or off 4 key Press this key to change sequential Instantaneous Max instantan...

Page 12: ...this key to switch to display date and time Press and hold this key while turning the meter on to the alarm setting mode press key two times to exit this mode 3 Press this key for 3 seconds to switch...

Page 13: ...itch to the manual data reading mode press this key again to exit this mode Press and hold this key while turning the meter on to disable the auto power off function the symbol will disappear 11 key S...

Page 14: ...value displayed 5 Low battery indication 6 Units mV m and V m Electric field strength A m and mA m Magnetic field strength W m2 mW m2 W m2 W cm2 and mW cm2 Power density 7 Measured value displayed as...

Page 15: ...the limit 13 hh mm ss Time displayed YY MM DD Date displayed 14 CAL Calibration factor indication or setting indication from 0 20 to 25 00 15 Z Z axis measured value displayed 16 Y Y axis measured va...

Page 16: ...source The operator must take care not to be between the source of disturbance and the zone to be checked the human body shields electromagnetic fields The E field sensor is isotropic it does not req...

Page 17: ...AX The digital display shows the highest instantaneous value measured the MAX symbol is displayed Maximum average MAX AVG The digital display shows the highest average value measured the MAX AVG symbo...

Page 18: ...for this application In many cases the measurement accuracy will be sufficient even if the frequency response of sensor calibration factor is ignored CAL can be set to 1 00 in such cases E Field typic...

Page 19: ...in the displayed V m unit Alarm limit function is only used for total three axial value comparator 4 5 Setting the meter 4 5 1 Setting the units of measurement With the key as follows X Y Z Z Y X 2 X...

Page 20: ...17 4 5 2 Setting the result mode Instantaneous result mode is automatically set when the meter is turned on With the key as followings MAX AVG MAX Instantaneous Max Instantaneous Max average...

Page 21: ...18 4 5 3 Setting the alarm limit value ALARM 2 2 2 X Y Z Z Y X 2 Z Y X 2 Power off Hold on 2 X Y Z Z Y X X Y Z X Y Z Z Y X...

Page 22: ...the meter to enter the alarm setting mode the mW m2 unit is flashing displayed 3 Press and keys to select the desired setting unit 4 Press key to enter the alarm value setting mode the one of four dig...

Page 23: ...SEt marks is displayed 3 Press or key to increase or decrease the value 4 Press key to store the new setting value and exit 4 5 5 Switching the alarm function on or off exceed limit value on off ALAR...

Page 24: ...ter again to disable the audible sound then the symbol will disappear from the display 4 5 7 Setting the auto power off function off Hold on Power off Auto power off symbol disappears When the meter i...

Page 25: ...work place or the interested areas as described above This is particularly important if the field conditions are unknown 3 Pay special attention to measuring the vicinity of possible radiation sources...

Page 26: ...ured values 4 7 1 Storing individual measured values Value stored indication Current memory location Starting with memory to location 01 The current memory location number appears in the lower right s...

Page 27: ...de indicate Reading memory location X Y Z 1 Press key the display then shows reading mode 2 Press or key to select the desired memory location 3 Press key to select the desired reading units 4 Press k...

Page 28: ...lay then shows CLr M and press key will exit and not clear memory 3 Press key to select to clear memory 4 Press to clear memory and exit 4 8 Setting current data and time 1 Press key to enter this mod...

Page 29: ...city 2 When the battery capacity below 5 the symbol is displayed and will auto power off after 5 minutes 3 Using AC adaptor to charging battery Plug the AC adaptor into the AC power socket Plug the AC...

Page 30: ......

Page 31: ......

Page 32: ...TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel 02 2799 3660 Fax 886 2 2799 5099 E Mail tes ms9 hinet net http www tes com tw Oct 2020...