TES TES-1322 Instruction Manual Download Page 2

3. Precautions: 

a). Do not operate the thermometer near the large 

electrical or magnetic fields. 

b). Keep the thermometer away from direct sunlight or 

strong source of light, hot objects (70

/158

), high 

temperatures, high humidity, or dust during using and 
storaging. 

c). If the thermometer was at the environment where’s 

temperature changes drastically, it would be fine to start 
measuring until the thermometer return to the stable 
status. 

d). Condensation may from on the focal lens if the 

thermometer was moved quickly form a cold to a hot 
environment.    Before taking measurements, pls. wait 

for the condensation to dissipate. 

e). Do not touch the focal lens. 

 

4. Environment conditions: 

a). Altitude up to 2000 meters. 
b). Relatively humidity 80% max. 
c). Operating Ambient 0 ~ 40

 

 

5. Maintenance & Clearing: 

a). Repairs or serving aren’t covered in this manual should 

only be performed by qualified personnel. 

b). Periodically wipe the case with a dry cloth.    Don’t use 

abrasives or solvents on this instrument. 

c). When serving, use only specified replacement parts. 

6. Safety symbols: 

     

Comply with EMC 

7. 

U.S. Pat. No. Des. 448,314

 

. FEATURES 

¾

 

 / 

 Selectable 

¾

 Back-light LCD display 

¾

 Laser targeting 

¾

 Emissivity adjustable 

¾

 Audible and visible alarm 

. SPECIFICATIONS 

3-1 General Information 

Display :   

Backlight LCD Display. 

Auto power off :   

Approx. 15sec. (Infrared) 

Over range indication :     “OL” or “-OL”. 

Low battery indication :   The 

  will be displayed in 

LCD when the battery voltage 
drops below the operating 

voltage. 

Power supply :   

Single 9V battery 006P 9V or 

IEC6F22, or NEDA1604. 

Battery life : 

  Approx. 50hours (laser pointer 

and backlight turn off) 

Operating temperature :     

   and humidity           0

 to 40

 (32

 to 104

),  

                                                  below 80%RH. 

 

Summary of Contents for TES-1322

Page 1: ...r It can be used to measure the temperature of objects surface that is improper to be measured by traditional contact thermometer such as moving object the surface with electricity current or the objects which are uneasy to be touched Ⅰ SAFETY INFORMATION 1 Read the following safety information carefully before attempting to operate or service the meter 2 use the meter only as specified in this ma...

Page 2: ...0 max c Operating Ambient 0 40 5 Maintenance Clearing a Repairs or serving aren t covered in this manual should only be performed by qualified personnel b Periodically wipe the case with a dry cloth Don t use abrasives or solvents on this instrument c When serving use only specified replacement parts 6 Safety symbols Comply with EMC 7 U S Pat No Des 448 314 2 Ⅱ FEATURES Selectable Back light LCD d...

Page 3: ...o with a 1 min target Emissivity 0 1 1 0 Sighting Laser marker 1mw class 2 Sensor Thermopile 4 Type K Measuring range 50 to 1333 58 to 1999 Resolution 0 1 1 0 1 1 Responding time once per second Basic accuracy 23 5 calibration accuracy are of reading degree at 18 to 28 with relative humidity up 80 Function Resolution Range Accuracy 50 0 0 2 rdg 1 0 0 1 0 200 0 1 rdg 0 8 1 200 1333 0 2 rdg 2 58 32 ...

Page 4: ... mode and mode settings selection a Press MODE button to select measuring mode Infrared thermometer Type K thermometer b Press MODE button for 3 seconds entering into the mode settings 6 Type K input connector 7 Laser aperture 8 Focal lens Ⅴ LCD DISPLAY DESCRIPTION 1 Low battery mark 6 Laser indicator 2 Maximum 7 Hold function 3 Negative polarity 8 Hi Alarm 4 Measure value 9 Lo Alarm 5 Unit 10 SET...

Page 5: ...lues Metals cont SURFACE EMISSIVITY Zinc oxidized 0 1 Galvanized iron 0 3 Tin plated steel 0 1 Gold polished 0 1 Silver polished 0 1 Chromium polished 0 1 Emissivity Values Non Metals Refractory Building Materials Red brick rough 0 75 to 0 9 8 Fire clay 0 75 Asbestos 0 95 Concrete 0 7 Marble 0 9 Carborundum 0 85 Plaster 0 9 Alumina fine grain 0 25 Alumina coarse grain 0 45 Silica fine grain 0 4 Si...

Page 6: ...95 10 Ⅶ TEMPERATURE MEASUREMENT 1 Infrared measuring a Infrared measuring Press MEAS button to power on the meter and start measuring Release MEAS button to stop measuring and auto hold the reading the meter will be off automatically after 15 secs b Under the Infrared measuring mode press hold MEAS button and press MODE button to select MAX measurement General measuring mode 2 Continuous infrared ...

Page 7: ...gs of infrared measurement if K doesn t appear in LCD 12 1 Parameter settings for Infrared measuring Under the infrared parameter setting mode LCD will show press MODE button to select in turn for setting ε ALMÇ ÈALM press MODE button again to escape the setting mode and return to the general measurement Note In the setting mode if users don t push any button in 15 seconds then it will escape from...

Page 8: ...ser light function will be disabled Ⅸ BATTERY REPLACEMENT 1 As battery power is not sufficient LCD will display replacement with one new battery type 9V is required 2 Open battery cover then take out the battery from instrument and replace with a new 9 Volt battery and place the battery cover back 14 TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel...

Reviews: