INTRODUCTION 

The Infrared Thermometer is digital and with type-K 
thermocouple input being a dual measurement product. 
Although the precised design in it, the hand-held Infrared 
Thermometer is easy for user to operate, in addition, the 
backlight illuminative function is helpful to user who is used 
to measure at the dark place.  Moreover, the Infrared 
Thermometer will show a Laser symbol in LCD as a 
reminder and its additional auto hold the reading & 

auto-power-off functions are practical to users. 

The Infrared Thermometer is a Non-contact thermometer 
with laser pointer.  It can be used to measure the 
temperature of objects’ surface that is improper to be 
measured by traditional (contact) thermometer (such as 
moving object, the surface with electricity current or the 
objects which are uneasy to be touched.) 

 

. SAFETY INFORMATION 

1. Read the following safety information carefully before 

attempting to operate or service the meter. 

2. use the meter only as specified in this manual ; otherwise, 

the protection provided by the meter may be impaired. 

 

Warning 

If user presses 

MEAS

 button while the 

  symbol is showing in 

LCD, then the meter will radiate the laser.    At this moment, user 
has to avoid the laser radiating to your eyes to prevent any hurts. 

˙

  If the measured object with smooth surface and will reflect the 

laser, pls. prevent the reflected laser to radiate your eyes. 

˙

  Pls. don’t radiate the laser to inflammable gas to avoid 

dangers. 

Summary of Contents for TES-1322

Page 1: ...r It can be used to measure the temperature of objects surface that is improper to be measured by traditional contact thermometer such as moving object the surface with electricity current or the objects which are uneasy to be touched Ⅰ SAFETY INFORMATION 1 Read the following safety information carefully before attempting to operate or service the meter 2 use the meter only as specified in this ma...

Page 2: ...0 max c Operating Ambient 0 40 5 Maintenance Clearing a Repairs or serving aren t covered in this manual should only be performed by qualified personnel b Periodically wipe the case with a dry cloth Don t use abrasives or solvents on this instrument c When serving use only specified replacement parts 6 Safety symbols Comply with EMC 7 U S Pat No Des 448 314 2 Ⅱ FEATURES Selectable Back light LCD d...

Page 3: ...o with a 1 min target Emissivity 0 1 1 0 Sighting Laser marker 1mw class 2 Sensor Thermopile 4 Type K Measuring range 50 to 1333 58 to 1999 Resolution 0 1 1 0 1 1 Responding time once per second Basic accuracy 23 5 calibration accuracy are of reading degree at 18 to 28 with relative humidity up 80 Function Resolution Range Accuracy 50 0 0 2 rdg 1 0 0 1 0 200 0 1 rdg 0 8 1 200 1333 0 2 rdg 2 58 32 ...

Page 4: ... mode and mode settings selection a Press MODE button to select measuring mode Infrared thermometer Type K thermometer b Press MODE button for 3 seconds entering into the mode settings 6 Type K input connector 7 Laser aperture 8 Focal lens Ⅴ LCD DISPLAY DESCRIPTION 1 Low battery mark 6 Laser indicator 2 Maximum 7 Hold function 3 Negative polarity 8 Hi Alarm 4 Measure value 9 Lo Alarm 5 Unit 10 SET...

Page 5: ...lues Metals cont SURFACE EMISSIVITY Zinc oxidized 0 1 Galvanized iron 0 3 Tin plated steel 0 1 Gold polished 0 1 Silver polished 0 1 Chromium polished 0 1 Emissivity Values Non Metals Refractory Building Materials Red brick rough 0 75 to 0 9 8 Fire clay 0 75 Asbestos 0 95 Concrete 0 7 Marble 0 9 Carborundum 0 85 Plaster 0 9 Alumina fine grain 0 25 Alumina coarse grain 0 45 Silica fine grain 0 4 Si...

Page 6: ...95 10 Ⅶ TEMPERATURE MEASUREMENT 1 Infrared measuring a Infrared measuring Press MEAS button to power on the meter and start measuring Release MEAS button to stop measuring and auto hold the reading the meter will be off automatically after 15 secs b Under the Infrared measuring mode press hold MEAS button and press MODE button to select MAX measurement General measuring mode 2 Continuous infrared ...

Page 7: ...gs of infrared measurement if K doesn t appear in LCD 12 1 Parameter settings for Infrared measuring Under the infrared parameter setting mode LCD will show press MODE button to select in turn for setting ε ALMÇ ÈALM press MODE button again to escape the setting mode and return to the general measurement Note In the setting mode if users don t push any button in 15 seconds then it will escape from...

Page 8: ...ser light function will be disabled Ⅸ BATTERY REPLACEMENT 1 As battery power is not sufficient LCD will display replacement with one new battery type 9V is required 2 Open battery cover then take out the battery from instrument and replace with a new 9 Volt battery and place the battery cover back 14 TES ELECTRICAL ELECTRONIC CORP 7F No 31 Lane 513 Rui Guang Road Neihu Dist Taipei Taiwan R O C Tel...

Reviews: