Maintenance
Disconnect the plug & switch off power supply from the source.
Needle Replacement
First remove the Lock (14).
Now rotate the front cover (4) counter clockwise.
Now slide out the needle supporter (13) along with needles (12) and spring (11).
Push the worn out needles (12) from the front side to remove from the needle supporter (13).
Replace the old needles with new one and assemble in reverse manner.
Carbon Brush Replacement
Remove the screws (26) from bottom to
disassemble the cover(25).
Now remove the cap (22) and pull the
carbon brush (21).
Replace with new one and assemble in
reverse manner.
Needle size Needle Part no.
Needle Supporter
Ø2
022 90 08 (53 No.s)
022 40 47
Ø3
022 90 04 (23 No.s)
022 40 45
FF-MM-319-Rev0
Page 5
Now slide out the needle supporter (13) along with needles (12) and spring (11).
Push the worn out needles (12) from the front side to remove from the needle supporter (13).
w one and assemble in reverse manner.